首页> 外文期刊>Environmental Science & Technology >A DGT Technique for Plutonium Bioavailability Measurements
【24h】

A DGT Technique for Plutonium Bioavailability Measurements

机译:DGT技术用于Bio生物利用度测量

获取原文
获取原文并翻译 | 示例
       

摘要

The toxicity of heavy metals in natural waters is strongly dependent on the local chemical environment. Assessing the bioavailability of radionuclides predicts the toxic effects to aquatic biota. The technique of diffusive gradients in thin films (DGT) is largely exploited for bioavailability measurements of trace metals in waters. However, it has not been applied for plutonium speciation measurements yet. This study investigates the use of DGT technique for plutonium bioavailability measurements in chemically different environments. We used a diffusion cell to determine the diffusion coefficients (D) of plutonium in polyacrybmide (PAM) gel and found D in the range of 2.06-2.29 × 10~(-6) cm~2 s~(-1). It ranged between 1.10 and 2.03 × 10~(-6) cm~2 s~(-1) in the presence of fulvic acid and in natural waters with low DOM. In the presence of 20 ppm of humic acid of an organic-rich soil, plutonium diffusion was hindered by a factor of 5, with a diffusion coefficient of 0.50 × 10~(-6) cm~2 s~(-1). We also tested commercially available DGT devices with Chelex resin for plutonium bioavailability measurements in laboratory conditions and the diffusion coefficients agreed with those from the diffusion cell experiments. These findings show that the DGT methodology can be used to investigate the bioaccumularion of the labile plutonium fraction in aquatic biota.
机译:天然水中重金属的毒性在很大程度上取决于当地的化学环境。评估放射性核素的生物利用度可预测对水生生物群的毒性作用。薄膜中的扩散梯度技术(DGT)被广泛用于测量水中痕量金属的生物利用度。但是,它尚未应用于applied形态的测量。这项研究调查了DGT技术在化学不同环境中for生物利用度测量中的应用。我们使用扩散池确定p在聚丙烯酰胺(PAM)凝胶中的扩散系数(D),发现D在2.06-2.29×10〜(-6)cm〜2 s〜(-1)范围内。在存在富里酸和低DOM的天然水中,其范围为1.10至2.03×10〜(-6)cm〜2 s〜(-1)。在腐殖酸含量为20 ppm的富含有机物的土壤中,p的扩散受阻5,扩散系数为0.50×10〜(-6)cm〜2 s〜(-1)。我们还用Chelex树脂测试了可商购的DGT设备,以在实验室条件下测量measurements的生物利用度,并且其扩散系数与扩散池实验得出的一致。这些发现表明,DGT方法可用于研究水生生物区中不稳定p组分的生物累积。

著录项

  • 来源
    《Environmental Science & Technology》 |2014年第18期|10829-10834|共6页
  • 作者单位

    Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland;

    Division of Radiation Protection, Federal Office of Public Health, Bern, Switzerland;

    Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland;

    Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 14:01:16

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号