首页> 外文期刊>Environmental Science & Technology >Monitoring Organic Pollutants in Waters Using the Diffusive Gradients in the Thin Films Technique: Investigations on the Effects of Biofouling and Degradation
【24h】

Monitoring Organic Pollutants in Waters Using the Diffusive Gradients in the Thin Films Technique: Investigations on the Effects of Biofouling and Degradation

机译:在薄膜技术中使用扩散梯度监测水中的有机污染物:对生物污染和降解影响的研究

获取原文
获取原文并翻译 | 示例
           

摘要

The diffusive gradients in thin films (DGT) passive sampling technique has been increasingly used to provide time-weighted average concentrations of the biorelevant fraction of organic contaminants in waters, with high spatial and temporal resolutions at low cost. This study was tested for the effects of biofouling and compound degradation/loss during sample handling/storage on the DGT measurement of a range of emerging organic pollutants. Biofouling was tested using biofilms collected from the influent and effluent of a typical urban wastewater treatment plant. Most (85%) target compounds showed no detectable effect on the DGT measurement when 8- and 15-day biofouled membrane filters were used. Four storage methods were designed to test for within-sampler degradation/loss for up to 2 months. Intact samplers can be simply stored in polyethylene bags at ambient temperature (18-26 °C) with most compounds stable (mass loss <20%) for at least 1 week. Keeping intact samplers at 4 °C or binding gels in solvent gave good recoveries, with most chemicals being stable for up to 2 months, although the best results were obtained when binding gels were kept in solvent at 4 °C. Recommendations are made for sample handling and storage of DGT samplers used for determination of trace organics in monitoring and surveillance campaigns.
机译:薄膜(DGT)被动采样技术的扩散梯度越来越多地用于提供水中有机污染物的生物密封级数的延时平均浓度,具有低成本的高空间和时间分辨率。该研究对在样品处理/储存过程中的生物污染和复合降解/损失的影响进行了测试,DGT测量一系列新兴有机污染物。使用从典型的城市污水处理厂的流水和流出物收集的生物膜测试生物污垢。大多数(85%)目标化合物对使用8-和15天的生物耦合膜过滤器时,对DGT测量没有任何可检测的影响。设计了四种存储方法,用于测试在取样器内降解/损耗长达2个月。完整采样器可以简单地在环境温度(18-26℃)的聚乙烯袋中,大多数化合物稳定(质量损失<20%)至少1周。保持完整的取样器在4℃下保持溶剂中的凝胶或结合凝胶,良好的回收率,大多数化学品稳定长达2个月,尽管当将结合凝胶保持在4℃时获得最佳结果。建议采用样品处理和储存DGT采样器,用于测定监测和监督活动中的痕量有机物。

著录项

  • 来源
    《Environmental Science & Technology》 |2020年第13期|7961-7969|共9页
  • 作者单位

    Lancaster Environment Centre Lancaster University Lancaster LA1 4YQ U.K.;

    Lancaster Environment Centre Lancaster University Lancaster LA1 4YQ U.K.;

    Lancaster Environment Centre Lancaster University Lancaster LA1 4YQ U.K.;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号