首页> 外文期刊>Environmental Science & Technology >Development and Validation of a Controlled Pressure Method Test Protocol for Vapor Intrusion Pathway Assessment
【24h】

Development and Validation of a Controlled Pressure Method Test Protocol for Vapor Intrusion Pathway Assessment

机译:蒸汽入侵路径评估控制压力法试验方案的开发与验证

获取原文
获取原文并翻译 | 示例
           

摘要

Controlled pressure method (CPM) testing is a building-specific diagnostic tool for vapor intrusion (Ⅵ) pathway assessment which offers advantages over traditional pathway assessment approaches. By manipulating the building pressure conditions, the CPM creates the worst-case Ⅵ impact and provides rapid insight into the type of vapor source(s). The primary barrier to general acceptance and use of this tool is the need for definitive guidance on test design parameters, such as the indoor-outdoor pressure difference (or exhaust fan flow rate), CPM test duration, exhaust fan location, and air sampling location(s) and conditions. This study focused on a systematic evaluation of each of these factors, which then led to the formulation of proposed CPM testing guidelines. The results suggest that CPM tests should be conducted with both negative and positive pressure indoor-outdoor differentials of about 10-15 Pa, and the tests should last for at least nine indoor air exchanges for negative pressure difference testing and four indoor air exchanges for positive pressure difference testing. Although exhaust fan intake sampling is sufficient to provide critical information to assess impacts during negative pressure testing, adding room-specific indoor air sampling to both negative and positive pressure difference testing can provide insight into vapor entry locations and indoor source contributions.
机译:受控压力法(CPM)测试是一种特定于蒸汽入侵(Ⅳ)途径评估的特定于蒸发诊断工具,其优于传统途径评估方法。通过操纵建筑压力条件,CPM创造了最坏情况ⅵⅵ撞击,并提供对蒸气源类型的快速洞察。一般接受和使用该工具的主要障碍是需要对测试设计参数的明确指导,例如室外压力差(或排气扇流量),CPM测试持续时间,排气扇位置和空气采样位置(s)和条件。本研究专注于对这些因素的系统评估,然后导致建议的CPM测试指南的制定。结果表明,CPM试验应以约10-15Pa的负压室室外室外差分进行,测试应持续至少九个室内空气交换,用于负压差检测和用于正面的四个室内空气交换压力差检测。尽管排气风扇进气采样足以提供关键信息以在负压测试期间评估影响,但为负压差检测添加房间特定的室内空气采样可以深入了解蒸气入口位置和室内源贡献。

著录项

  • 来源
    《Environmental Science & Technology》 |2020年第12期|7117-7125|共9页
  • 作者单位

    School of Sustainable Engineering and the Built Environment Ira A Fulton Schools of Engineering Arizona State University Tempe Arizona 85287 United States;

    School of Sustainable Engineering and the Built Environment Ira A Fulton Schools of Engineering Arizona State University Tempe Arizona 85287 United States;

    Department of Civil and Environmental Engineering Colorado School of Mines Golden Colorado 80401 United States;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);