首页> 外文期刊>Environment international >Indoor air pollution and exposure assessment of the gulf cooperation council countries: A critical review
【24h】

Indoor air pollution and exposure assessment of the gulf cooperation council countries: A critical review

机译:海湾合作委员会国家的室内空气污染和暴露评估:严格审查

获取原文
获取原文并翻译 | 示例
       

摘要

Indoor air pollution is one of the human health threat problems in the Gulf Cooperation Council (GCC) countries. In these countries, due to unfavorable meteorological conditions, such as elevated ambient temperature, high relative humidity, and natural events such as dust storms, people spend a substantial amount of their time in indoor environments. In addition, production of physical and biological aerosols from air conditioners, cooking activities, burning of Arabian incense, and overcrowding due to pilgrimage programs are common causes of low quality indoor air in this region. Thus, due to infiltration of outdoor sources as well as various indoor sources, people living in the GCC countries are highly exposed to indoor air pollutants. Inhalation of indoor air pollutants causes mortalities and morbidities attributed to cardiorespiratory, pulmonary, and lung cancer diseases. Hence, the aim of this review study is to provide a summary of the major findings of indoor air pollution studies in different microenvironments in six GCC countries. These include characterization of detected indoor air pollutants, exposure concentration levels, source identifications, sustainable building designs and ventilation systems, and the mitigation strategies. To do so, 130 relevant indoor air pollution studies across the GCC countries were critically reviewed. Particulate matters (PM10 and PM2.5), total volatile organic compounds (TVOCs), carbon dioxide (CO2), sulfur dioxide (SO2), nitrogen dioxide (NO2), and heavy metals were identified as the reported indoor air pollutants. Apart from them, indoor Radon and bioaerosols were studied only in specific GCC countries. Thus, future studies should also focus on the investigation of emerging indoor air pollutants, such as ultrafine and nanoparticles and their associated health effects. Furthermore, studies on the mitigation of indoor air pollution through the development of advanced air purification and ventilation systems could improve the indoor air quality (IAQ) in the GCC region.
机译:室内空气污染是海湾合作委员会(GCC)国家的人类健康威胁问题之一。在这些国家中,由于不利的气象条件,例如环境温度升高,相对湿度高以及沙尘暴等自然事件,人们在室内环境中花费了大量时间。此外,从空调生产物理和生物气雾剂,烹饪活动,燃烧阿拉伯香和朝圣计划引起的人满为患是该地区室内空气质量低下的常见原因。因此,由于室外源以及各种室内源的渗透,居住在海湾合作委员会国家的人们高度暴露于室内空气污染物中。吸入室内空气污染物会导致因心肺,肺和肺癌疾病引起的死亡和发病。因此,本综述研究的目的是对六个海湾合作委员会国家不同微环境中室内空气污染研究的主要发现进行总结。其中包括检测到的室内空气污染物的特征,暴露浓度水平,源识别,可持续建筑设计和通风系统以及缓解策略。为此,对海湾合作委员会(GCC)国家中的130多项相关室内空气污染研究进行了严格审查。已报告室内空气污染物为颗粒物(PM10和PM2.5),总挥发性有机化合物(TVOC),二氧化碳(CO2),二氧化硫(SO2),二氧化氮(NO2)和重金属。除此之外,仅在特定的海湾合作委员会国家中研究了室内Rad和生物气溶胶。因此,未来的研究还应集中于对新兴室内空气污染物(如超细颗粒和纳米颗粒)及其相关健康影响的研究。此外,通过开发先进的空气净化和通风系统来减轻室内空气污染的研究可以改善海湾合作委员会地区的室内空气质量(IAQ)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号