A hybrid air treatment cooling system (HATCS) has been proposed to simultaneously promote energy efficiency and improve indoor air quality (IAQ). The HATCS involves a plug-and-play air treatment system. It comprises an energy-efficient oxygen production process, an ozone-based oxidation treatment unit, and an air scrubbing device. Experimental studies have been carried out to investigate the air-purification performance and the energy consumption performance. To address the issue of outdoor air pollution, the proposed HATCS has demonstrated its capability to reduce the supply of ambient polluted air and maintain an acceptable IAQ Experimental data have demonstrated the feasibility of employing a higher chilled water supply temperature through the cooling coil due to the reduced outdoor air intake. In addition, case studies have been carried out to investigate the energy consumption performance of the proposed HATCS in a typical office building under tropical climates. Simulation results have indicated that a lower outdoor air flow rate leads to a significant reduction on total electricity consumption for cooling. For the selected cases, it is estimated that the total annual electricity consumption saving is up to 59.3 kWh/m(2) by employing the air treatment system. (C) 2019 Elsevier Ltd. All rights reserved.
机译:已经提出了一种混合空气处理冷却系统(HATCS),以同时提高能源效率并改善室内空气质量(IAQ)。 HATCS涉及即插即用的空气处理系统。它包括一个节能的氧气生产过程,一个基于臭氧的氧化处理装置和一个空气洗涤装置。已经进行了实验研究以研究空气净化性能和能量消耗性能。为了解决室外空气污染的问题,拟议的HATCS展示了其减少环境污染空气供应并保持可接受的IAQ的能力。实验数据表明,由于冷却盘管采用较高的冷却水供应温度是可行的。减少室外进气。此外,已经进行了案例研究,以研究拟议的HATCS在热带气候下的典型办公大楼中的能耗性能。仿真结果表明,较低的室外空气流量会显着降低用于冷却的总电力消耗。对于选定的案例,通过使用空气处理系统,估计每年可以节省的总电量高达59.3 kWh / m(2)。 (C)2019 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Energy》 |2019年第1期|1016-1026|共11页
  • 作者

    Cui X.; Islam M. R.; Chua K. J.;

  • 作者单位

    Xi An Jiao Tong Univ, Inst Bldg Environm & Sustainable Technol, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China|Natl Univ Singapore, Dept Mech Engn, 9 Engn Dr 1, Singapore 117576, Singapore;

    Natl Univ Singapore, Dept Mech Engn, 9 Engn Dr 1, Singapore 117576, Singapore|Natl Univ Singapore, Engn Sci Programme, 9 Engn Dr 1, Singapore 117575, Singapore;

    Natl Univ Singapore, Dept Mech Engn, 9 Engn Dr 1, Singapore 117576, Singapore|Natl Univ Singapore, Engn Sci Programme, 9 Engn Dr 1, Singapore 117575, Singapore;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Air-conditioning; Ventilation; Cooling load; Energy consumption; Indoor air quality;

    机译:空调;通风;制冷负荷;能耗;室内空气质量;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号