Effect of Coordinated Air Pollution Control Devices in Coal-Fired Power Plants on Arsenic Emissions

机译:燃煤电厂空气污染协调控制装置对砷排放的影响

获取原文
获取原文并翻译 | 示例
       

摘要

An arsenic emission study was performed, at nine coal-fired power plants in China and the U.S. that are equipped with various air pollution control devices (APCDs). On average, over 90% of arsenic in the flue gas is captured by the dry particulate matter collection system. Less than 3% of arsenic remains in the boiler slag, and 3% is captured by the desulfurization system. Another 1% is captured by wet precipitators. The remaining arsenic is emitted from the stack. Ultralow-emission technology with a low-temperature economizer before the electrostatic precipitator (ESP) promotes the capture of more arsenic compounds. It was found that reactions between arsenic and the denitrification catalyst make it difficult to reach a perfect arsenic mass balance in a power plant, excluding plants that are equipped with a hot ESP installed before the selective catalytic reduction system. Arsenic speciation greatly depends upon the temperature of the flue gas and the location of the measurement. There are no significant differences between U.S. and Chinese coals with regard to the behavior, of arsenic during combustion and its interaction with power plant APCD systems.
机译:在中国和美国的9个装有各种空气污染控制装置(APCD)的燃煤发电厂进行了砷排放研究。平均而言,烟道气中90%以上的砷被干式颗粒物收集系统捕获。锅炉炉渣中残留的砷不到3%,脱硫系统捕获了3%。另有1%被湿式除尘器捕获。剩余的砷从烟囱中排出。静电除尘器(ESP)之前具有低温节能器的超低排放技术可促进更多砷化合物的捕集。已经发现,砷与脱氮催化剂之间的反应使电厂难以达到理想的砷质量平衡,除了在选择性催化还原系统之前装有热电除尘器的电厂外。砷的形态在很大程度上取决于烟气的温度和测量的位置。就燃烧过程中砷的行为及其与电厂APCD系统的相互作用而言,中美煤炭之间无显着差异。

著录项

  • 来源
    《Energy & fuels》 |2017年第7期|7309-7316|共8页
  • 作者单位

    North China Elect Power Univ, Minist Educ, Key Lab Condit Monitoring & Control Power Plant E, Beijing 102206, Peoples R China;

    North China Elect Power Univ, Minist Educ, Key Lab Condit Monitoring & Control Power Plant E, Beijing 102206, Peoples R China;

    North China Elect Power Univ, Minist Educ, Key Lab Condit Monitoring & Control Power Plant E, Beijing 102206, Peoples R China;

    Western Kentucky Univ, Inst Combust Sci & Environm Technol, Bowling Green, KY 42101 USA;

    Lehigh Univ, Energy Res Ctr, 117 ATLSS Dr, Bethlehem, PA 18015 USA;

    North China Elect Power Univ, Minist Educ, Key Lab Condit Monitoring & Control Power Plant E, Beijing 102206, Peoples R China;

    North China Elect Power Univ, Minist Educ, Key Lab Condit Monitoring & Control Power Plant E, Beijing 102206, Peoples R China|Western Kentucky Univ, Inst Combust Sci & Environm Technol, Bowling Green, KY 42101 USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 00:39:37

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号