Sulphur hexafluoride (SF_6) gas-insulated substations (GIS) are exposed to the same types of overvoltages as conventional substations, such as lightning overvoltages, switching overvoltages and temporary overvoltages. Possible means to limit overvoltages in a GIS are active gap (SiC) surge arresters and metal oxide (ZnO) surge arresters. The objective of this work is to study the effects of the system configuration on the performance of these two types of overvoltage limiting devices. The results obtained from the study are presented and discussed, and some general conclusions are suggested.
机译:六氟化硫(SF_6)气体绝缘变电站(GIS)承受与常规变电站相同类型的过电压,例如雷电过电压,开关过电压和临时过电压。限制GIS中过电压的可能方法是有源间隙(SiC)电涌放电器和金属氧化物(ZnO)电涌放电器。这项工作的目的是研究系统配置对这两种类型的过压限制设备的性能的影响。提出并讨论了从研究中获得的结果,并提出了一些一般性结论。