The efficiency of a two-column cryogenic ASU (air separation unit) that is part of an IGCC (integrated gasification combined cycle) can be increased significantly by making better use of the heat of compression and by improving the heat integration of the distillation columns. The rational exergy efficiency of the ASU, which is defined as the desired increase in exergy content of the products divided by the amount of work that is added to the process, can be increased from 35% to over 70%. The exergy destruction per amount of feed is reduced with 1.6 kJ/mol air, corresponding to a 0.74% increase in the net electric efficiency of the IGCC. The efficiencies are expected to increase even further because the full potential of using heat-integrated distillation columns is not yet achieved.
机译:通过更好地利用压缩热并改善蒸馏塔的热集成,可以显着提高作为IGCC(整体气化联合循环)一部分的两塔式低温ASU(空气分离装置)的效率。 ASU的合理火用效率(可以定义为产品的火用含量的期望增加量除以添加到该过程中的工作量)可以从35%增加到70%以上。用1.6 kJ / mol的空气减少了单位进料的火用破坏,相当于IGCC的净电效率提高了0.74%。由于尚未实现使用热集成蒸馏塔的全部潜力,因此效率有望进一步提高。