Field study on indoor thermal comfort of office buildings using evaporative cooling in the composite climate of India

机译:印度复合气候蒸发冷却办公楼室内热舒适的现场研究

获取原文
获取原文并翻译 | 示例
           

摘要

Thermal adaptation can play a significant role in defining thermal comfort levels for evaporatively cooled office buildings commonly found in India. However, there are no dedicated studies to record the occupant perception and indoor thermal comfort in these buildings. The contribution of adaptive thermal comfort theory on occupant perception remains unclear for accurate design and operation of evaporatively cooled office buildings in India. Therefore, a multi-year field study of thermal comfort was conducted in ten office buildings operated under evaporative cooling systems in the composite climate of Jaipur, India. Transverse type questionnaire following Class II measurement protocols was carried out for recording office occupant's sensation and preferences for different indoor variables using ASHRAE 55 seven point and five-point scales, respectively. A total of 1554 datasets were collected spread over a total period of eighteen months, covering the entire summer season which includes very hot and dry days as well as few rainy days. Comfort temperature calculated using the Griffiths method was found 28.8 degrees C (SD= +/- 1.9 degrees C). Results from the field study showed acceptable indoor humidity and airspeed range of 35-85% and 0.75-1.5m/s for office subjects. Furthermore, 80% and 90% acceptability limits based on operative temperature and SET* were determined for present field surveys and results were compared with the existing adaptive models in National Building Code of India for different building types. This work is the first step towards the formation of an adaptive comfort model for evaporatively cooled buildings in the composite climate of India. (C) 2019 Elsevier B.V. All rights reserved.
机译:热适应可以在为印度常见的蒸发冷却的办公楼定义蒸发冷却的办公楼的热舒适度方面发挥重要作用。但是,没有专门的研究可以在这些建筑物中记录乘员感知和室内热舒适度。适应性热舒适理论对乘员感知的贡献仍不清楚印度蒸发冷却办公楼的准确设计和运行。因此,在印度斋浦尔复合气候的蒸发冷却系统下运行的十大办公建筑中进行了多年的热舒适性研究。 II类测量协议之后的横向型问卷进行用于记录办公室乘员的感觉和使用ASHRAE 55七点和五点尺度的不同室内变量的偏好。共收集了1554个数据集,在18个月的总期间蔓延,覆盖整个夏季,其中包括非常热和干燥的日子以及雨天很少。使用GRIFFITHS方法计算的舒适温度为28.8摄氏度(SD = +/- 1.9c)。现场研究的结果显示出可接受的室内湿度和空速范围为35-85%和0.75-1.5M / s用于办公室。此外,基于手术温度和设定的80%和90%的可接受性限制对于目前的现场调查,并将结果与​​印度国家建筑码的现有自适应模型进行比较。这项工作是迈向印度复合气候中蒸发冷却建筑的适应性舒适模型的第一步。 (c)2019 Elsevier B.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号