首页> 外文期刊>IEEE Transactions on Electromagnetic Compatibility >A method for measuring transients caused by interrupting current using a transmission line terminated in its characteristics impedance
【24h】

A method for measuring transients caused by interrupting current using a transmission line terminated in its characteristics impedance

机译:一种使用特性阻抗终止的传输线测量由中断电流引起的瞬变的方法

获取原文
获取原文并翻译 | 示例
           

摘要

A measurement method of transients caused by interrupting a current is described. In consideration of the fast transients and high-frequency discharge phenomena due to interrupting the current, a transmission-line system was introduced. It consists of a coaxial switch, coaxial cables as transmission lines on the right and left sides of the switch, and termination resistors. When the current is interrupted by the switch, the waveform across the termination resistor is measured by an oscilloscope. The impedance-matching technique for the cables was employed to minimize the effects of reflected waves. That is, the resistors were designed to match the characteristic impedance of the cables. The characteristics of the system were measured by a network analyzer. The VSWR of the system was within 1.33 in the frequency range below 500 MHz. The time-domain measurement using a transmission-line system terminated in its characteristic impedance clears up the process of the complicated transients caused by interrupting current.
机译:描述了一种由中断电流引起的瞬变的测量方法。考虑到由于电流中断而引起的快速瞬变和高频放电现象,引入了一种传输线系统。它由同轴开关,同轴电缆作为开关左右两侧的传输线以及终端电阻组成。当电流被开关中断时,终端电阻两端的波形由示波器测量。电缆的阻抗匹配技术用于最大程度地减少反射波的影响。即,电阻器被设计为匹配电缆的特性阻抗。该系统的特性由网络分析仪测量。在低于500 MHz的频率范围内,系统的VSWR在1.33以内。使用终止于其特征阻抗的传输线系统进行时域测量,可以消除由中断电流引起的复杂瞬变过程。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号