Voltage sag index calculation: Comparison between time-domain simulation and short-circuit calculation

机译:电压骤降​​指数计算:时域仿真与短路计算之间的比较

获取原文
获取原文并翻译 | 示例
           

摘要

This paper describes a case study where voltage sags indices are estimated using Monte Carlo approach combined with ATP (Alternative Transient Program) and short-circuit calculation program. Voltage sag magnitude and frequency are used to evaluate the correlation between both programs. The results indicate that time-domain simulation and short-circuit calculation gives similar voltage sag indices. Considering the high correlation between the results, short-circuit calculation programs are preferable over the time-domain simulation tools as the modelling for time-domain simulation is more complex, time consuming, and rarely covers the whole network.
机译:本文介绍了一个案例研究,其中使用蒙特卡罗方法结合ATP(替代瞬态程序)和短路计算程序来估算电压骤降指数。电压暂降幅度和频率用于评估两个程序之间的相关性。结果表明,时域仿真和短路计算给出了相似的电压跌落指数。考虑到结果之间的高度相关性,与时域仿真工具相比,短路计算程序更可取,因为时域仿真的建模更为复杂,耗时,并且很少覆盖整个网络。