Voltage Sags are the most disturbing power quality deviation to the sensitive industrial loads causing production losses and other impacts to the equipment end users and distributors of electricity. A new methodology for estimation of voltage sag patterns and clustering of distribution substations with similar features for voltage sags is the main contribution of this paper. The focus is on the regulation of this phenomenon in Brazil. Network modeling and faults simulations in transmission and distribution levels were performed in a Brazilian actual distribution system with 17 substations in order to get information regarding the number of voltage sags caused in the substations bus bars. Principal Component Analysis was applied on a significant number of variables containing relevant information of power quality and design features of the substations and storing the major Principal Components Scores. Furthermore, Clusters of substations with similar characteristics to voltage sags were formed and assigned a specific Membership to each substation. The expected annual number of voltage sags is the solution. A 95% Confidence Interval for the total number of voltage sags was estimated, leading to the classification of the main variables related to the voltage sags by clusters formed. Clusters of Substations with similarities for regulatory purpose of voltage sags were the principal results, followed by classification of the main variables associated with voltage sags by the clusters formed. A critical analysis of the results and a comparison among different Clustering Methods reaffirmed the assertiveness of the proposed methodology for the management of power quality associated with voltage sags, by the Regulator and the distribution utilities in Brazil. (C) 2016 Elsevier B.V. All rights reserved.
机译:电压骤降​​是对敏感工业负载造成的最令人不安的电能质量偏差,从而导致生产损失以及对设备最终用户和配电商的其他影响。本文的主要贡献是一种新的方法来估算电压暂降模式和具有相似特征的配电变电站聚类。重点是在巴西管理这一现象。在具有17个变电站的巴西实际配电系统中,进行了传输和配电级别的网络建模和故障模拟,以获取有关变电站母线中引起的电压骤降数量的信息。主成分分析应用于大量变量,这些变量包含变电站的电能质量和设计特征的相关信息,并存储主要的主成分得分。此外,形成了具有与电压骤降相似特征的变电站集群,并为每个变电站分配了特定的成员资格。解决方案是预期的年度电压骤降次数。估计电压骤降总数的95%置信区间,从而根据形成的群集对与电压骤降相关的主要变量进行分类。主要结果是变电站的群集,这些群集具有用于电压暂降的相似调节目的,其次是根据形成的群集对与电压暂降相关的主要变量进行分类。对结果的严格分析和不同聚类方法之间的比较,再次证实了巴西监管机构和配电公司提出的用于管理与电压暂降相关的电能质量的方法的主张。 (C)2016 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Electric power systems research》 |2016年第7期|31-42|共12页
  • 作者单位

    Fed Univ Itajuba UNIFEI, Ave BPS,1303 Bairro Pinheirinho,Caixa Postal 50, BR-37500903 Itajuba, MG, Brazil|IFES Fed Inst Espirito Santo, Estr Tartaruga S-N, BR-29215090 Guarapari, ES, Brazil;

    Fed Univ Itajuba UNIFEI, Ave BPS,1303 Bairro Pinheirinho,Caixa Postal 50, BR-37500903 Itajuba, MG, Brazil;

    Fed Univ Itajuba UNIFEI, Ave BPS,1303 Bairro Pinheirinho,Caixa Postal 50, BR-37500903 Itajuba, MG, Brazil;

    Fed Univ Itajuba UNIFEI, Ave BPS,1303 Bairro Pinheirinho,Caixa Postal 50, BR-37500903 Itajuba, MG, Brazil;

    Fed Univ Itajuba UNIFEI, Ave BPS,1303 Bairro Pinheirinho,Caixa Postal 50, BR-37500903 Itajuba, MG, Brazil;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Voltage sag; Principal component analysis; Cluster; Regulator;

    机译:电压暂降;主成分分析;集群;调节器;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号