This study proposes a method for stator fault detection of inverter-fed induction machine in closed-loop control. The sideband response of inverter switching harmonics in common-mode voltage (CMV) is employed to detect the stator inter-turn fault, thus no additional injected signal is necessary. However, the PWM nature harmonics introduce undesired CMV signals, depending on the inherent imbalance or resistance asymmetry. For this reason, the CMV amplitude is not suitable to indicate the fault directly. In this study, the behaviour of switching harmonic is analysed first, and then a simple but efficient stator fault model is demonstrated. To suppress the adverse interference from inverter, an inter-turn fault indicator is proposed by utilising both of the switching sidebands. This method can obtain fault location and severity with low sensitivity to steady operating condition and stator imbalance. The experimental results validate the effectiveness of the proposed method.
机译:该研究提出了一种闭环控制中的逆变式感应电机定子故障检测方法。共模电压(CMV)中采用逆变器开关谐波的边带响应来检测定子匝间故障,因此无需额外的注入信号。但是,取决于固有的不平衡或电阻不对称性,PWM自然谐波会引入不希望的CMV信号。因此,CMV振幅不适合直接指示故障。在这项研究中,首先分析了开关谐波的行为,然后展示了一个简单而有效的定子故障模型。为了抑制来自逆变器的不利干扰,提出了利用两个开关边带的匝间故障指示器。该方法可以获得故障位置和严重性,并且对稳定运行条件和定子不平衡的敏感性较低。实验结果验证了该方法的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号