This paper presents an investigation of the effects of the duration of earthquake ground motion on the peak displacement and total dissipated cumulative energy in seismic isolation systems designed by the procedures of ASCE/SEI 7-16. The seismic isolation systems considered in this study are elastomeric with lead and natural rubber bearings and sliding in the form of single and triple friction pendulum bearings. Long- and short-duration ground motions were selected so that the 5%-damped spectral acceleration values of each motion were closely matched over periods of 0.05 to 6 s. The results of the analysis demonstrate that the duration of ground motions have insignificant effects on the isolation system peak displacement-particularly in the lower bound conditions and sliding isolation bearings-but have important effects on the total cumulative energy for all conditions. This has implications in the testing of isolators, which are presented in an evaluation of the isolator test procedures of the ASCE/SEI 7-16 standard. The evaluation reveals that, if the cumulative energy dissipated by the isolation system is used as the controlling criterion, the specified tests are generally appropriate for locations characterized by short-duration ground motions, but are unconservative for locations where long-duration motions are anticipated. Additional results and discussion demonstrate that the cumulative energy may not be an appropriate criterion for designing isolator tests as it may lead to unrealistic demands on the tested isolators.
机译:本文介绍了地震地面运动持续时间对由ASCE / SEI 7-16程序设计的地震隔离系统峰值位移和完全消散累积能量的调查。本研究中考虑的地震隔离系统是具有铅和天然橡胶轴承的弹性体,并以单摩擦摆动轴承的形式滑动。选择长期和短持续时间的接地运动,使每个运动的5%探测器光谱加速度与0.05至6秒的时期紧密匹配。分析结果表明,地面运动的持续时间对隔离系统峰位的影响微不足道,特别是在下限条件下和滑动隔离轴承 - 但对所有条件的总累积能量具有重要影响。这对隔离器的测试有影响,这在评估ASCE / SEI 7-16标准的分离器测试程序中呈现。评估揭示了,如果用隔离系统散散的累积能量用作控制标准,则规定的测试通常适用于特征在于短持续时间接地运动的位置,但是对于预期长持续时间运动的位置是未填写的位置。其他结果和讨论表明,累积能量可能不是设计隔离器测试的适当标准,因为它可能导致测试隔离器上的不切实际的要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号