A new degradation model for safety cables in nuclear power plants that incorporates the critical antioxidant concentration concept is proposed in order to account for the effect of antioxidants and to simulate several synergisms in various thermal and radiation environments. A chemical reaction scheme is used to represent oxidation reactions via the decomposition of peroxide radicals. The effects of antioxidants are included in this scheme in order to demonstrate critical concentration phenomena. In addition, diffusion equations are added to the reaction rate equations to enable reproduction of diffusion-limited oxidation. Such a degradation model with antioxidant effects is discussed for degradation behaviors in polymers used for safety cables under various dose rates and temperature conditions, and its effectiveness is verified.
机译:提出了一种新的核电厂安全电缆降解模型,该模型结合了关键的抗氧化剂浓度概念,目的是考虑抗氧化剂的作用并模拟在各种热和辐射环境中的几种协同作用。化学反应方案用于表示通过过氧化物自由基分解的氧化反应。该方案包括抗氧化剂的作用,以证明临界浓度现象。另外,将扩散方程式添加到反应速率方程式中以使得能够再现扩散受限的氧化。讨论了这种具有抗氧化作用的降解模型,用于在各种剂量率和温度条件下用于安全电缆的聚合物中的降解行为,并验证了其有效性。