The results of the commercial indicator gas tube investigation, using the time delay measuring method are presented in this paper. This tube is usually used as an indicator of many electrical appliances. Time delay distributions for voltages from 75 V up to 100 V and relaxation times from 1 ms to 20 ms are presented. The time delay distributions for voltages U > 75 V have Gaussian shape, and for U = 75 V are multimodal. The multimodal time delay distributions indicate several different mechanisms which lead to breakdown. It is also shown that gas discharge tube has very small memory effect, which indicates fast response after the long (out of use) time, and consequently good characteristic for indicator tube. This characteristic of the used commercial indicators gas discharge tubes is consequence of gas tube geometry causing several processes which lead to breakdown under the same experimental conditions.
机译:本文介绍了使用时延测量方法进行的商用指示气管研究的结果。该管通常用作许多电器的指示器。给出了从75 V到100 V的电压以及从1 ms到20 ms的弛豫时间的时间延迟分布。电压U> 75 V的时间延迟分布具有高斯形状,而对于U = 75 V的时间延迟分布则是多峰的。多峰时间延迟分布表明了导致故障的几种不同机制。还显示出气体放电管具有非常小的记忆效果,这表明长时间(不使用)时间后响应很快,因此指示管具有良好的特性。所使用的商用指示器气体放电管的这一特征是气体管几何形状的结果,该几何形状导致若干过程,这些过程导致在相同实验条件下发生故障。