首页> 外文期刊>International journal of hyperthermia: The official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group >Percutaneous radiofrequency ablation near large vessels in beagle livers: the impact of time and distance on the ablation zone
【24h】

Percutaneous radiofrequency ablation near large vessels in beagle livers: the impact of time and distance on the ablation zone

机译:猎犬肝脏附近大血管附近的经皮射频消融:时间和距离对消融区的影响

获取原文
           

摘要

Purpose To investigate the effects of ablation time and distance between the radiofrequency ablation (RFA) electrode tip and a large vessel on the ablation zone in beagle livers. Methods Sixty-one percutaneous RFA coagulation zones were created near large vessels in 10 beagle livers in?vivo . The ablated lesions were divided into four groups based on ablation time and distance between the electrode tip and a large vessel (group A, 3?min 0.5?cm; group B, 3?min 0?cm; group C, 5?min 0.5?cm; group D, 5?min 0?cm). The ablated area, long-axis diameters, short-axis diameters, and vessel wall injury were examined. Results With a fixed ablation time, the ablation zone created with the electrode tip at 0.5?cm from the large vessel was significantly larger than at 0?cm ( p ?.05). At a fixed distance between the electrode tip and vessel, the ablation zone created for 5?min was significantly larger than for 3?min ( p ?.05). The frequency of vessel wall injury in the 0?cm groups was significantly higher than that in the 0.5?cm groups (37.5% vs. 6.9%; p =?.003, odds ratio, 7.43). The ratio of width to depth (Dw/Dz) was larger in the 0.5 cm groups than in the 0 cm groups ( p ?.001). Conclusion The ablation zone increased with longer ablation times and greater distances between the RFA tip and large vessels for perivascular lesions. The distance between the needle tip and blood vessels is an important factor that affects the overall ablation outcome.
机译:目的探讨射频消融(RFA)电极尖端和大容器在比猎犬肝脏的消融时间和距离之间的影响。方法在10颗比格肝中的大血管附近产生六十次经皮RFA凝血区。基于电极尖端和大容器之间的消融时间和距离分为四组烧蚀的病变(A,3?min0.5≤cm; b,3≤min0≤cm;组,5?min 0.5组?cm; d组,5?min 0?cm)。检查消融区域,长轴直径,短轴直径和血管壁损伤。通过固定消融时间,用电极尖端产生的消融区在大容器0.5Ωcm处显着大于0≤cm(p <。05)。在电极尖端和容器之间的固定距离处,产生5Ω分钟的消融区显着大于3?min(p <。05)。血管壁损伤的频率在0≤CM基团中显着高于0.5Ω基团的频率(37.5%vs.6.9%; p =α.003,odds比,7.43)。在0.5cm组中,宽度与深度(dw / dz)的比率越大,而不是0cm基团(p <。001)。结论消融区随着较长的消融时间和RFA尖端和大容量延长血管内病变而增加。针尖和血管之间的距离是影响整体消融结果的重要因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号