A Beam-Specific Optimization Target Volume for Stereotactic Proton Pencil Beam Scanning Therapy for Locally Advanced Pancreatic Cancer

机译:用于局部晚期胰腺癌的立体定向质子铅笔梁扫描治疗的比光束优化目标体积

获取原文
   

获取外文期刊封面封底 >>

       

摘要

PurposeWe investigate two margin-based schemes for optimization target volumes (OTV), both isotropic expansion (2 mm) and beam-specific OTV, to account for uncertainties due to the setup errors and range uncertainties in pancreatic stereotactic pencil beam scanning (PBS) proton therapy. Also, as 2-mm being one of the extreme sizes of margin, we also study whether the plan quality of 2-mm uniform expansion could be comparable to other plan schemes.Methods and MaterialsWe developed 2 schemes for OTV: (1) a uniform expansion of 2 mm (OTV2mm) for setup uncertainty and (2) a water equivalent thickness–based, beam-specific expansion (OTVWET) on beam direction and 2 mm expansion laterally. Six LAPC patients were planned with a prescribed dose of 33 Gy (RBE) in 5 fractions. Robustness optimization (RO) plans on gross tumor volumes, with setup uncertainties of 2 mm and range uncertainties of 3.5%, were implemented as a benchmark.ResultsAll 3 optimization schemes achieved decent target coverage with no significant difference. The OTV2mmplans show superior organ at risk (OAR) sparing, especially for proximal duodenum. However, OTV2mmplans demonstrate severe susceptibility to range and setup uncertainties with a passing rate of 19% of the plans meeting the goal of 95% volume covered by the prescribed dose. The proposed dose spread function analysis shows no significant difference.ConclusionsThe use of OTVWETmimics a union volume for all scenarios in robust optimization but saves optimization time noticeably. The beam-specific margin can be attractive to online adaptive stereotactic body proton therapy owing to the efficiency of the plan optimization.
机译:目的威研究了两个基于边缘的优化目标体积(OTV)的方案,各向同性膨胀(2 mm)和比梁特定的OTV,以考虑由于设置错误和胰腺定向铅笔束扫描(PBS)质子中的设定误差和范围不确定性的不确定性治疗。此外,由于2毫米是边缘的极端尺寸之一,我们还研究了2毫米均匀的膨胀的平面质量是否可以与其他计划方案相当。方法和材料开发了2个OTV的方案:(1)均匀扩展2 mm(OTV2mm)的设置不确定性和(2)在光束方向上的水当量厚度,光束特异性膨胀(OTVWET)横向膨胀2mm。计划六种LAPC患者在5分级分中具有规定的33 GY(RBE)。鲁棒性优化(RO)在总肿瘤卷上的计划,设置不确定性为2毫米,范围不确定性为3.5%,被实施为基准。结果3优化方案实现了不显着差异的体面的目标覆盖率。 OTV2MMPLANS在风险(OAR)备件下显示出优越的器官,特别是对于近端十二指肠。然而,OTV2MMPLANS表现出对范围和设置不确定性的严重敏感性,并在满足规定剂量涵盖的目标95%体积的目标中的19%的速率为19%。所提出的剂量传播函数分析显示没有显着差异。结论OTVWETMICICS在强大的优化中使用ENGWETMICICS的所有场景,但明显节省优化时间。由于计划优化的效率,光束特定的边缘可能对在线适应性立体定向体质子疗法具有吸引力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号