BACKGROUND:A qualitative fit test using bitter-tasting aerosols is the commonest way to determine filtering face-piece (FFP) mask leakage. This taste test is subjective and biased by placebo. We propose a cheap, quantitative modification of the taste test by measuring the amount of fluorescein stained filter paper behind the mask using image analysis.METHODS:A bitter-tasting fluorescein solution was aerosolised during mask fit tests, with filter paper placed on masks' inner surfaces. Participants reported whether they could taste bitterness to determine taste test 'pass' or 'fail' results. Filter paper photographs were digitally analysed to quantify total fluorescence (TF).RESULTS:Fifty-six healthcare professionals were fit tested; 32 (57%) 'passed' the taste test. TF between the taste test 'pass' and 'fail' groups was significantly different (p0.001). A cut-off (TF = 5.0 × 10 6 units) was determined at precision (78%) and recall (84%), resulting in 5/56 participants (9%) reclassified from 'pass' to 'fail' by the fluorescein test. Seven out of 56 (12%) reclassified from 'fail' to 'pass'.CONCLUSION:Fluorescein is detectable and sensitive at identifying FFP mask leaks. These low-cost adaptations can enhance exiting fit testing to determine 'pass' and 'fail' groups, protecting those who 'passed' the taste test but have high fluorescein leak, and reassuring those who 'failed' the taste test despite having little fluorescein leak.? Royal College of Physicians 2021. All rights reserved.
机译:背景:使用苦味品尝气溶胶的定性拟合试验是确定过滤面部件(FFP)掩模泄漏的最常识方法。这种味道测试是受安慰剂的主观和偏见。我们通过使用图像分析测量掩模后面的荧光素染色过滤纸的量来提出廉价的定量修饰。表面。参与者报告他们是否可以品尝苦味,以确定味觉测试'通过'或“失败”的结果。滤纸照片经过数字分析以量化总荧光(TF)。结果:56名医疗保健专业人员进行了认证; 32(57%)'通过'味道测试。味道测试“通道”和“失败”组之间的TF显着不同(P <0.001)。截止(TF = 5.0×10 6个单位)以精确度(78%)确定并召回(84%),导致5/56参与者(9%)重新分类从荧光素的“失败”测试。 56(12%)中的七个(12%)从“FAIL”到'PASS'.Conclusion:荧光素是可检测到的,敏感在识别FFP掩模泄漏。这些低成本的适应可以增强退出的拟合测试,以确定“通过”和“失败”群体,保护那些“通过”味道测试但具有高荧光素泄漏的人,尽管有很少的荧光素,但仍有高荧光素泄漏的人。泄漏。?皇家医师学院2021.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号