Minimum 7‐year Follow‐up of A Porous Coated Trabecular Titanium Cup Manufactured with Electron Beam Melting Technique in Primary Total Hip Arthroplasty

机译:在初级总髋关节置换术中使用电子束熔化技术制造的多孔涂层小梁杯的最低7年随访

获取原文
           

摘要

Objectives To investigate the cup survivorship, patient satisfaction level, clinical function, and radiographic outcomes of patients who underwent total hip arthroplasty (THA) using electron beam melting (EBM)‐produced porous coated titanium cups at mid‐term follow up. Methods A total of 32 patients (32 hips) from five hospitals in China who underwent primary THA using EBM‐produced trabecular titanium cups between May and December 2012 were retrospectively reviewed. The inclusion criteria were: (i) patients who underwent THA with the use of EBM‐produced cups with possible 7‐year follow up; and (ii) patients with follow‐up information, including the cup survivorship, patient satisfaction level, and clinical outcomes such as Harris hip score. The exclusion criteria were: (i) patients with neuropathic diseases; and (ii) patients who underwent THA due to neoplastic disease. Five (15.6%) patients were lost to follow up before the 7‐year follow‐up and, thus, were excluded; none of these patients died due to disease associated with the THA or had undergone removal of their cups as of our last evaluation. The mean age and body mass index of the patients were 59.37 (range: 38.00–69.00) years and 24.51 (range: 16.50–34.10) kg/m 2 , respectively. Thirteen (48.1%) of the patients were female. Results The average duration of follow‐up was 93.48 (range: 89.00–99.00) months. The median Harris hip score improved from 42.00 (interquartile range: 37.00–49.00) to 97.00 (interquartile range: 92.00–97.00) at the latest follow up ( P ?0.001). A total of 18 (66.7%) patients rated their satisfaction level as very satisfied, 6 (22.2%) as satisfied, 2 (7.4%) as neutral and 1 (3.7%) as dissatisfied. No intraoperative or postoperative complications were identified. At the latest follow up, all cups were considered to have achieved osteointegration fixation, with three or more of the five signs evident in the most recent X‐ray. However, three cups revealed radiolucent lines with a width of less than 1?mm. The median vertical and horizontal distances between the latest postoperative center of rotation relative to the anatomic center of rotation were 2.50 (interquartile range: ?3.10, 6.94) mm superiorly and 3.26 (interquartile range: ?8.12, 2.38) mm medially, respectively, at the most recent postoperative follow up. Kaplan–Meier survivorship analysis of cups, with the endpoint defined as postoperative radiolucent lines of less than 1?mm in width in at least two zones, reveals that the 8.25‐year survival was 96.3% (95% confidence interval: 76.49%–99.47%). Conclusion The mid‐term follow‐up of patients who underwent primary THA using EBM‐produced porous coated titanium cups demonstrated favorable patient satisfaction, good clinical function, excellent survivorship, and adequate biological fixation.
机译:探讨使用电子束熔化(EBM)的患者患者患者患者患者患者患者的婴儿养老症,患者满意度,临床功能和射线照相结果 - 在中期跟进时进行多孔涂层的钛杯。方法回顾性审查了在中国5月和12月之间使用ebm制作的小梁钛杯,在中国52名医院中共有32名患者(32髋)。纳入标准是:(i)随着使用ebm制作的杯子的患者接受了可能的7年的后续行动; (ii)患有随访信息的患者,包括杯生生存,患者满意度和哈里斯臀部评分等临床结果。排除标准是:(i)患有神经性疾病的患者; (ii)由于肿瘤疾病而接受过THA的患者。五(15.6%)患者在7年的随访前失去了跟进,因此被排除在外;这些患者均未因与THA相关的疾病而死亡,或者经历了他们的最后一次评估的杯子。患者的平均年龄和体重指数分别为59.37(范围:38.00-69.00)年和24.51(范围:16.50-34.10)kg / m 2。十三个(48.1%)的患者是女性。结果随访的平均持续时间为93.48(范围:89.00-99.00)个月。最近的跟进(P& 0.001),中位哈里斯髋关节评分从42.00(四分位数:37.00-49.00)到97.00(第37.00-49.00)至97.00(第92.00-97.00)(92.00-97.00)。共18例(66.7%)患者评定了他们满意的水平,非常满意,6(22.2%)至满意,2(7.4%)为中性,1(3.7%),如不满意。没有确定术中或术后并发症。在最新的后续,所有杯子被认为已经实现了骨整折固定,其中三个或更多的五个迹象在最近的X射线中明显明显。然而,三个杯子揭示了宽度小于1Ωmm的无辐射线。最新术后旋转中心相对于解剖旋转旋转中心之间的中位垂直和水平距离为2.50(晶体范围:?3.10,6.94)mm和3.26(四分位数:?8.12,2.38)mm,在最近的术后跟进。 Kaplan-Meier对杯子的生存分析,终点被定义为至少两个区域的宽度小于1?mm的术后无射线,表明8.25岁的存活率为96.3%(95%置信区间:76.49%-99.47 %)。结论使用EBM生产的多孔涂层钛杯接受初级THA的患者的中期随访表明患者满意度,良好的临床功能,优异的生存和充足的生物固定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号