首页> 外文期刊>Medicine. >Bispectral index monitoring of the clinical effects of propofol closed-loop target-controlled infusion
【24h】

Bispectral index monitoring of the clinical effects of propofol closed-loop target-controlled infusion

机译:双光谱指数监测异丙酚闭环靶控制输液的临床疗效

获取原文
           

摘要

BACKGROUND:To investigate whether closed-loop systems under bispectral index anesthesia depth monitoring can reduce the intraoperative propofol dosage.METHODS:All randomized controlled trials (RCTs) on reducing propofol dosage under closed-loop systems were collected, and the literature was screened out, the abstracts and full texts were carefully read, and the references were tracked, data extraction and quality evaluation were conducted on the included research, and the RevMan5.3 software was used for meta-analysis. The main results were propofol and the incidence of adverse reactions such as hypertensive hypotension and postoperative cognitive dysfunction. A total of 879 cases were included in 8 articles, including 450 occurrences in the closed-loop system group and 429 cases in the open-loop system group.RESULTS:Compared with manual control, closed-loop systems under bispectral index anesthesia depth monitoring reduced the dose of propofol (MD: -0.62, 95% CI: -1.08--0.16, P?=?.008), with heterogeneity (I2?=?80%). Closed-loop systems significantly reduced the incidence of abnormal blood pressure (MD: -0.02, 95%CI: -0.05-0.01, P?=?.15, I2?=?74%) and postoperative cognitive dysfunction (MD: -0.08, 95% CI: -0.14 -0.01, P?=?.02, I2?=?94%).CONCLUSION:Bispectral index monitoring of propofol closed-loop target-controlled infusion system can reduce the amount of propofol, reduce the incidence of adverse reactions such as hypertensive or hypotension and postoperative cognitive dysfunction.Copyright ? 2021 the Author(s). Published by Wolters Kluwer Health, Inc.
机译:背景:为了调查双光谱指数麻醉深度监测下的闭环系统是否可以减少术中的异丙酚剂量。收集闭环系统下还原异丙酚剂量的所有随机对照试验(RCT),并筛选出文献,摘要仔细阅读摘要和全文,并跟踪参考文献,对包括的研究进行了数据提取和质量评估,Revman5.3软件用于Meta分析。主要结果是异丙酚和不良反应的发生率,如高血压性低血压和术后认知功能障碍。 8篇文章中共有879例,包括450个闭环系统组出现,开环系统集团429例。结果:与手动控制,双光谱指数麻醉深度监测下的闭环系统相比减少了减少具有异质性的异丙酚(MD:-0.62,95%CI:-1.08-0.16,P≤0.0.16),具有异质性(I2?= 80%)。闭环系统显着降低异常血压的发生率(MD:-0.02,95%CI:-0.05-0.01,P?=α.15,I2?= 74%)和术后认知功能障碍(MD:-0.08 ,95%ci:-0.14 -0.01,p?=α.02,i2,i2?= 94%)。结论:双光谱指数监测异丙酚闭环靶控制输液系统可以减少异丙酚的量,降低发病率不良反应,如高血压或低血压和术后认知功能障碍。 2021提交人。由Wolters Kluwer Health,Inc。出版

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号