...
首页> 外文期刊>BMC Ophthalmology >Analysis of corneal astigmatism and aberration in chinese congenital cataract and developmental cataract patients before cataract surgery
【24h】

Analysis of corneal astigmatism and aberration in chinese congenital cataract and developmental cataract patients before cataract surgery

机译:白内障手术前中国先天性白内障和发育白内障患者角膜散差和畸变分析

获取原文
           

摘要

To investigate the distribution of corneal astigmatism, aberration, and biometric parameters in Chinese congenital cataract (CC) /developmental cataract patients before cataract surgery. We evaluated eyes of CC /developmental cataract patients scheduled for cataract surgery from January 2016 to September 2019. Astigmatism, aberrations, and biometric parameters were measured with the Pentacam Scheimpflug imaging device (Pentacam HR, Oculus). Cataract was diagnosed and classified by slit-lamp examination after full mydriasis. We evaluated 538 eyes in 356 patients. The mean values of anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), and total corneal astigmatism (TCA) were determined as 1.98?±?1.06 D (range 0.0?4.8 D), 0.49?±?0.26 D (range 0.0?1.9 D), and 2.09?±?1.19 D (range 0.2?8.8 D), respectively. ACA and TCA?≥?1.25 D was present in 379 eyes (70.3%) and 392 eyes (72.8%), respectively. PCA between 0.25 D and 0.75 D was found in 380 eyes (70.6%). There was a statistically significant positive linear correlation between lower-order aberrations root mean square values (LOA RMS) and corneal astigmatism (CA). Furthermore, in terms of distribution of central cornea thickness, anterior chamber depth, ACA, PCA, and TCA in different types of cataracts, ACA was highest in patients with zonular cataracts. Finally, we found anterior corneal measurements may overestimate WTR astigmatism, underestimate ATR astigmatism, and underestimate oblique astigmatism, respectively. Most CC /developmental cataract patients had moderate to high astigmatism and ACA accounted for the largest proportion in the zonular group. This can provide a basis for planning of CC/developmental cataract surgery by ophthalmologists in clinical practice.
机译:探讨白内障手术前中国先天性白内障(CC​​)/发育性白内障患者角膜散发,畸变和生物识别参数的分布。我们评估了2016年1月至2019年1月的白内障手术的CC /发育性白内障患者的眼睛。用偏见的Scheimpflug成像装置(Pentacam Hr,Oculus)测量散光,畸变和生物识别参数。在全索霉病后,通过狭缝灯检查被诊断和分类的白内障。我们在356名患者中评估了538只眼睛。确定前角膜散散(ACA),后角膜散散(PCA)和总角膜散差(TCA)的平均值确定为1.98≤≤1.06d(范围0.0≤4.8d),0.49?±0.26 d(范围0.0?1.9d)和2.09?±1.19d(范围为0.2?8.8d)。 ACA和TCA?≥≤1.25d分别存在于379只眼(70.3%)和392只眼睛(72.8%)中存在。在380只眼睛(70.6%)中发现了0.25 d和0.75 d之间的PCA。低阶像差均均值(LOA rms)和角膜散差(CA)之间存在统计上显着的正线性相关性。此外,在不同类型的白内障中的中央角膜厚度,前室深度,ACA,PCA和TCA的分布方面,ACA在患有分区白内障的患者中最高。最后,我们发现前角膜测量可以高估WTR散光,低估ATR散光,分别低估倾斜散光。大多数CC /发育性白内障患者中度至高散光,ACA占Zonular组中最大比例。这可以为临床实践中的眼科医生规划CC /发育性白内障手术的基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号