首页> 外文期刊>BMC Cardiovascular Disorders >Successful double-layer metal stents rotational ablation under 2-dimensional and 3-dimensional optical coherence tomography guidance: a case report
【24h】

Successful double-layer metal stents rotational ablation under 2-dimensional and 3-dimensional optical coherence tomography guidance: a case report

机译:成功的双层金属支架旋转消融在二维和三维光学相干断层扫描指南下:案例报告

获取原文

摘要

Stent ablation with rotational atherectomy has been considered a bail-out strategy for the treatment of severe stent underexpansion. Only a few reports have yet shown rotational ablation for double-layer metal struts. We present a case of 80-year-old female patient presented to our hospital because of worsening effort angina. Coronary angiography revealed severe in-stent restenosis in the proximal left anterior descending artery. Optical coherence tomography (OCT) examinations found that severe stenosis occurred at the overlap region with 2-layer underexpanded stents and circumferential calcification beneath them. Under the guidance of 2-dimensional (2D) and 3-dimensional (3D) OCT, we successfully performed percutaneous coronary intervention (PCI) of this lesion after adequate stent ablation, high-pressure balloon dilatation, and subsequent everolimus-eluting stent implantation. The patient recovered well uneventfully and discharged from hospital 7?days later. No restenosis occurred after 12?months. We report a very rare case of in-stent restenosis due to double-layer underexpanded stents. The entire percutaneous coronary intervention procedure was performed step by step under the guidance of high-resolution OCT. Our findings highlight the specific value of 2D and 3D OCT guidance in double-layer stents rotational ablation.
机译:具有旋转形态切除术的支架消融已被认为是治疗严重支架Underexion的纾困策略。只有少数报道尚未显示双层金属支柱的旋转消融。我们提出了一个80岁女性患者,因为努力恶化而呈现给我们的医院。冠状动脉造影显示在近端左前期下降动脉中的严重支架再狭窄。光学相干断层扫描(OCT)检查发现,在重叠区域发生严重的狭窄,其中2层底部不足的支架和它们下方的周向钙化。在二维(2D)和三维(3D)OCT的指导下,我们在足够支架消融,高压球囊扩张和随后的血管血管洗脱支架植入后成功地进行了这种病变的经皮冠状动脉干预(PCI)。患者恢复良好的良好状态,并从医院7日出院,后几天。 12月后没有发生重新狭窄。我们报告了由于双层Underexpanded支架引起的非常罕见的支架再狭窄。整个经皮冠状动脉干预程序在高分辨率的指导下逐步进行。我们的研究结果突出了双层支架旋转消融中的2D和3D OCT指导的特定值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号