Fire scenario of street canyon, in which buildings had different heights, was investigated by Large Eddy Simulation (LES). To figure out the impact of street canyon layout on the smoke transportation behavior, side buildings in street canyon with different heights were built in this study. Simulation results showed that two regimes existed in the flow pattern of buoyancy plume. The critical re-entrainment phenomenon was defined as a critical criterion between the regimes. When the horizontal wind velocity exceeded the critical value, fire smoke would re-flow into the street canyon. An improved Froude number (Fr) considering the height difference of street canyon side buildings was proposed to quantify the dispersion pattern of fire smoke plume. The investigation showed that the Froude number was consistent when the critical re-entrainment wind velocities reached in different street canyons.
机译:大型涡流模拟(LES)调查了街道峡谷的火灾情景,其中建筑物有不同的高度。 要弄清楚街道峡谷布局对烟雾运输行为的影响,这项研究建立了街道峡谷的侧建筑。 模拟结果表明,浮力羽流的流动模式中存在两种制度。 关键的重新夹带现象被定义为制度之间的关键标准。 当水平风速超过临界值时,火烟会重新流入街道峡谷。 考虑到街道峡谷侧建筑物的高度差异的改进的FRoude号码(FR),以量化火烟羽的分散模式。 调查表明,当在不同的街道峡谷到达的关键重新夹具风速时,弗劳德数量是一致的。