To evaluate the accuracy and performance of the Autof MS1000 mass spectrometer in bacteria and yeast identification, 2342 isolates were obtained from microbial cultures of clinical specimens (e.g. blood, cerebrospinal fluid, respiratory tract samples, lumbar puncture fluid, wound samples, stool, and urine) collected in 2019 in Henan Provincial People’s Hospital. Repetitive strains from the same patient were excluded. We tested the Autof MS1000 and Bruker Biotyper mass spectrometry systems and the classical biochemical identification system VITEK 2/API 20C AUX. Inconsistencies in strain identification among the three systems were identified by 16S rDNA and gene sequencing. At the species level, the Autof MS1000 and Bruker Biotyper systems had isolate identification accuracies of 98.9 and 98.5%, respectively. At the genus level, the Autof MS1000 and Bruker Biotyper systems were 99.7 and 99.4% accurate, respectively. The instruments did not significantly differ in identification accuracy at either taxonomic level. The frequencies of unreliable identification were 1.1% (26/2342) for the Autof MS1000 and 1.5% (34/2342) for the Bruker Biotyper. In vitro experiments demonstrated that the coincidence rate of the Autof MS1000 mass spectrometer in the identification of five types of bacteria was ?93%, the identification error rate was ?3%, and the no identification rate was 0. This indicates that the Autof MS1000 system is acceptable for identification. The Autof MS1000 mass spectrometer can be utilised to identify clinical isolates. However, an upgradation of the database is recommended to correctly identify rare strains.
机译:为了评估Autof MS1000质谱仪在细菌和酵母鉴定中的准确性和性能,从临床样本的微生物培养物中获得2342个分离物(例如血液,脑脊液,呼吸道样品,腰刺穿液,伤口样品,粪便和尿液)于2019年在河南省人民医院收集。排除了来自同一患者的重复菌株。我们测试了Autof MS1000和Bruker Biotyper质谱系统和经典的生化识别系统Vitek 2 / API 20C Aux。通过16S rDNA和基因测序鉴定了三种系统中应变鉴定的不一致。在物种级别,Autof MS1000和Bruker Biotyper系统分别分离98.9和98.5%的鉴定精度。在属级,Autof MS1000和Bruker Biotyper系统分别为99.7和99.4%的精确。该仪器在分类学水平的鉴定准确性上没有显着差异。对于Bruker Biotyper的Autof MS1000和1.5%(34/2342),不可靠鉴定的频率为1.1%(26/2342)。体外实验表明,Autof MS1000质谱仪在鉴定五种细菌中的重合率为GT; 93%,鉴定误差率为0.3%,并且没有识别率为0.这表明Autof MS1000系统可以接受识别。 AUTOF MS1000质谱仪可用于识别临床分离株。但是,建议使用数据库的升级来正确识别罕见的菌株。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号