首页> 外文期刊>Journal of nuclear medicine technology >Development of Simple Methods to Reduce the Exposure of the Public to Radiation from Patients Who Have Undergone 18 F-FDG PET/CT
【24h】

Development of Simple Methods to Reduce the Exposure of the Public to Radiation from Patients Who Have Undergone 18 F-FDG PET/CT

机译:开发简单方法,以减少公众曝光的辐射,从而达到18个F-FDG PET / CT的患者

获取原文
           

摘要

At a time when reducing the radiation dose to patients and the public has become a major focus, we assessed the radiation exposure rate from patients after an 18 F-FDG PET/CT scan and evaluated different interventions to reduce it. Methods: We enrolled 100 patients, divided into 2 groups. For both groups, the radiation dose rate was measured with an ionization survey meter immediately after the scan. For group 1, the patients then voided and their dose rate was measured again. For group 2, the patients waited 30 min before voiding, and we measured the dose rate before (group 2A) and after (group 2B) they voided. Results: In total, 74 of the 100 patients exceeded the 20 μSv/h (2 mR/h) threshold immediately after the scan. In group 1, the mean dose rate decreased by 20.0% from the postscan measurement, with 12 of 36 remaining at or above 20 μSv/h. In group 2A, the mean dose rate decreased by 23% from the postscan measurement, with 9 of 38 remaining at or above 20 μSv/h. In group 2B, the mean dose rate decreased by 35% from the postscan measurement, with 1 of 38 remaining at 20 μSv/h. Conclusion: Nearly 75% of patients undergoing an 18 F-FDG PET/CT scan exceed 20 μSv/h when leaving the imaging facility. The most effective method to reduce radiation exposure was to have the patient void 30 min after the examination.
机译:在将辐射剂量减少到患者和公众已成为一个重大关注时,我们评估了18个F-FDG PET / CT扫描后患者的辐射暴露率,并评估了不同的干预措施以减少它。方法:我们注册了100名患者,分为2组。对于这两组,扫描后立即用电离测量计测量辐射剂量率。对于第1组,然后患者停止并且它们再次测量它们的剂量率。对于第2组,患者在排尿前等待30分钟,并测量以前的剂量率(组2A)和后(第2B组)的剂量率。结果:扫描后,100例患者的总共74例超过20μSV/ h(2 mr / h)阈值。在第1组中,平均剂量率从课程测量减少了20.0%,其中12个剩余为20μSV/ h。在第2A组中,平均剂量率从课程测量中减少了23%,其中9个剩余为20μSV/ h。在第2B组中,平均剂量率从课程测量率下降了35%,其中3个剩余38个以20μSV/ h。结论:近75%的患者在离开成像设施时经过18 F-FDG PET / CT扫描超过20μSV/ h。减少辐射暴露的最有效的方法是在检查后30分钟使患者空隙。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号