Results of the initial calibration of the Ultra-Violet Imaging Telescope (UVIT) were reported earlier by Tandon et al.The results reported earlier were based on the ground calibration as well as the first observations in orbit.Some additional data from the ground calibration and data from more in-orbit observations have been used to improve the results.In particular, extensive new data from in-orbit observations have been used to obtain (a) new photometric calibration that includes (i) zero points, (ii) flat fields, and (iii) saturation; (b) sensitivity variations; (c) spectral calibration for the near ultraviolet (NUV; 2000–3000 ?) and far ultraviolet (FUV; 1300–1800 ?) gratings; (d) point-spread function; and (e) astrometric calibration including distortion.Data acquired over the last three years show continued good performance of UVIT with no reduction in sensitivity in both UV channels.
机译:Tandon等人之前报道了超紫色成像望远镜(UVIT)的初始校准的结果。前面报告的结果基于地面校准以及轨道中的第一个观察结果。有些附加数据来自地面校准和 来自更多内轨观测的数据已被用于改进结果。特别地,来自轨道观测的广泛的新数据已被用于获得(a)新的光度校准,包括(i)零点,(ii)平面 ,(iii)饱和; (b)敏感性变化; (c)近紫外线(CUV; 2000-3000?)和远紫外线(FUV; 1300-1800?)光栅的光谱校准; (d)点传播功能; (e)在过去三年中获得的畸变包括畸变的校准表明UVIT的持续良好性能,无紫外线通道中的灵敏度降低。