首页> 外文期刊>Engineering journal >Biopolymer Test Kit for Colorimetric Detection of Chlorine in Water
【24h】

Biopolymer Test Kit for Colorimetric Detection of Chlorine in Water

机译:用于水中氯的比例检测的生物聚合物检测试剂盒

获取原文
           

摘要

The objective of the study was to fabricate the colorimetric sensor of biodegradable material for free chlorine determination. The colorimetric reagent of N,N-diethyl-p-phenylenediamine sulfate (DPD) was entrapped in the hybrid biopolymer film of agar (AG) and tapioca starch (TAS) and it was coated on the plastic micro-PCR tube. The pink product obtained from the reaction between DPD reagent and chlorine could indicate the presence of residual chlorine in the water. The condition for the sensor film synthesis was optimized by the digital image analytical technique with mobile phone application. The results were showed that Red-Green-Blue (RGB) intensity of reaction product was not changed, even through the DPD reagent was added over 0.2 g/mL. The addition of 16 g/L EDTA in the buffer solution could reduce the interference effect from some metals, especially Fe3+, contaminated in water sample. The water pH could be maintained for best analysis at the volume ratio between buffer and DPD solution of 0.5:1. The incubation of colorimetric film at 60 °C and 60 minutes provided the best sensor performance with fast analysis of 1 min reaction time. In conjunction with the digital image colorimetry (DIC), the developed test kit did not provided only the qualitative information, but the rapid quantitative analysis could be also fulfilled. A wide linear range of 0.3 to 15 mg/L chlorine concentration with good linearity (R2 > 0.99) was achieved by this coupled technique. The application of biopolymer film to various kind of real water samples showed the good performances, which were comparable with the standard spectrophotometry (no significantly different results at 95% confidence level). These could promote the use of biopolymer test kit as the environmentally-friendly analytical method for chlorine in water.
机译:该研究的目的是制造用于游离氯测定的可生物降解材料的比色传感器。将N,N-二乙基-P-苯二胺硫酸盐(DPD)的比色试剂捕获在琼脂(Ag)和木薯淀粉(Tas)的杂交生物聚合物膜中,并涂在塑料微PCR管上。从DPD试剂和氯之间的反应获得的粉红色产物可以表明水中存在残留的氯。通过移动电话应用的数字图像分析技术优化了传感器膜合成的条件。结果表明,即使通过DPD试剂也加入0.2g / ml,均未改变反应产物的红绿蓝(RGB)强度。在缓冲溶液中添加16g / l EDTA可以减少一些金属,特别是Fe3 +的干扰效果,污染水样。可以保持水pH值,以便在0.5:1的缓冲液和DPD溶液之间的体积比上进行最佳分析。在60℃和60分钟的比色膜孵育提供最佳的传感器性能,快速分析1分钟的反应时间。结合数字图像比色法(DIC),开发的测试套件未仅提供定性信息,但也可以满足快速定量分析。通过该偶联的技术实现了具有良好线性度(R2> 0.99)的0.3至15mg / L氯浓度的宽线性范围。生物聚合物膜在各种真实水样中的应用显示出良好的性能,与标准分光光度法相当(在95%置信水平下没有显着不同)。这些可以促进使用生物聚合物测试试剂盒作为水中氯的环保分析方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号