首页> 外文期刊>Advances in civil engineering >Experimental Analysis of Bending Stiffness Characteristics of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure
【24h】

Experimental Analysis of Bending Stiffness Characteristics of Grouted Double Mortise-Tenon Joint for Prefabricated Metro Station Structure

机译:预制地铁站结构灌浆双榫接头弯曲刚度特性的实验分析

获取原文
           

摘要

The grouted mortise-tenon joint, invented as the connection between the large prefabricated components, is the key to the prefabricated underground structures, and the double-tenon joint is most widely used in the prefabricated metro station structure. This paper conducts characteristic analysis of bending stiffness with a 1?:?1 prototype test in key working direction of different joint types for grouted double mortise-tenon joint. The results show that the double-tenon joint is characteristic of variable stiffness under different loads. Change laws of double-tenon joint bending stiffness without and with auxiliary pretightening device in tension side and compression side are also discussed. The correlations for calculating double-tenon joint bending stiffness with various axial loads and bending moments are derived at last, which offers the theory foreshadowing of similar joints.
机译:灌浆的榫眼关节,作为大型预制组件之间的连接,是预制地下结构的关键,双榫接头最广泛应用于预制地铁站结构。 本文对弯曲刚度进行了1?:1在灌浆双榫眼关节的不同关节类型的关键工作方向上的原型试验的特征分析。 结果表明,双榫接头是不同负载下可变刚度的特征。 还讨论了张力侧和压缩侧的双榫关节弯曲刚度的改变规律,包括张力侧和压缩侧的辅助气化装置。 最后导出了用各种轴向载荷和弯曲力度计算双榫关节弯曲刚度的相关性,其提供了具有类似关节的理论预示。