首页> 外文期刊>Scientific reports. >Accuracy assessment of a novel semiautomatic method evaluating bone grafts around the dental implant: an in vitro and ex vivo study
【24h】

Accuracy assessment of a novel semiautomatic method evaluating bone grafts around the dental implant: an in vitro and ex vivo study

机译:一种新型半自动方法评估牙科植入物周围的新型半自动方法的准确性评估:体外和exvivo研究

获取原文
       

摘要

The present study aimed to evaluate the accuracy and repeatability of morphological contour interpolation (MCI)-based semiautomatic segmentation method for volumetric measurements of bone grafts around dental implants. Three in vitro (one with a cylinder and two with a geometrically complex form) and four ex vivo models (peri-implant cylinder-shaped bone defect) were created for imitating implant placement with simultaneous guided bone regeneration (GBR) procedure. Cone beam computerized tomography (CBCT) scans of all models were obtained with the same parameters. For volumetric measurements, the actual volumes of bone grafts in models were assessed by computer-aided calculation and both manual and MCI-based methods were utilized as test methods. The accuracy of the methods was evaluated by comparing the measured value and the actual volume. The repeatability was assessed by calculating the coefficients of variation of repeated measurements. For the accuracy of three dimensional (3D) reconstructions, the computer-designed corresponding models were set as the reference and the morphological deviation of 3D surface renderings created by two methods were evaluated by comparing with reference. Besides, measurement time was recorded and a comparison between the two methods was performed. High accuracy of the MCI-based segmentation method was found with a discrepancy between the measured value and actual value never exceeding???7.5%. The excellent repeatability was shown with coefficients of variation never exceeding 1.2%. The MCI-based method showed less measurement time than the manual method and its 3D surface rendering showed a lower deviation from the reference.
机译:本研究旨在评估形态轮廓插值(基于MCI)的半自动分段方法的准确性和可重复性,用于牙科植入物周围骨移植物的体积测量。三个体外(一个带气缸和两个具有几何复杂形式的一个)和四种前体内模型(Peri注入圆柱形骨缺损),用于模仿植入物放置,同时引导骨再生(GBR)程序。通过相同的参数获得了所有型号的锥形光束计算机断层扫描(CBCT)扫描。对于体积测量,通过计算机辅助计算评估模型中骨移植的实际体积,并且手动和基于MCI的方法都用作测试方法。通过比较测量值和实际体积来评估方法的准确性。通过计算重复测量的变异系数来评估可重复性。对于三维(3D)重建的准确性,通过与参考相比,将计算机设计的相应模型设置为参考作为参考,并通过两种方法创建的3D表面渲染的形态偏差。此外,记录测量时间并进行两种方法之间的比较。发现基于MCI的分段方法的高精度在测量值与实际值之间的差异永远不会超过??? 7.5%。显示出优异的重复性,变异系数从未超过1.2%。基于MCI的方法显示比手动方法更少的测量时间,其3D表面渲染显示与参考的偏差较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号