In the paper the simulations of the low enthalpy energy source for brine-to-water heat pump using EED software had been presented. Authors indicated the influence of the ground parameters’ assumptions on the low enthalpy heat pump’s energy source simulation’s results. Based on the real borehole geological profile and data available in literature, the ground thermal conductivity coefficients have been calculated making different assumptions concerning the ground thermal properties. The calculated ground thermal conductivity coefficients along with the calculated source sizes, heat pump parameters and the heated building thermal performance served as the input data for the simulation software. The outcomes of the analyses include the temperatures of brine entering the heat pump as well as the brine initial temperature. Outcomes served for the low enthalpy energy source performance evaluation.
机译:本文介绍了使用EED软件的盐水热泵低焓能源的模拟。作者表明了地面参数对低焓热泵能源仿真结果的影响。基于实际钻孔地质型材和文献中可用的数据,已经计算了地面导热系数,制造了有关地面热性质的不同假设。计算出的接地导热系数随着计算的源尺寸,热泵参数和加热的建筑热性能作为仿真软件的输入数据。分析结果包括进入热泵以及盐水初始温度的盐水温度。结果用于低焓能源绩效评估。