首页> 外文期刊>International journal of infectious diseases : >Comparison of Xpert MTB/RIF (G4) and Xpert Ultra, including trace readouts, for the diagnosis of pulmonary tuberculosis in a TB and HIV endemic setting
【24h】

Comparison of Xpert MTB/RIF (G4) and Xpert Ultra, including trace readouts, for the diagnosis of pulmonary tuberculosis in a TB and HIV endemic setting

机译:XPERT MTB / RIF(G4)和XPERT Ultra的比较,包括痕量读数,用于诊断TB和HIV流行设定中的肺结核诊断

获取原文
           

摘要

Background There are limited data about Xpert-Ultra performance in different settings, in HIV-infected persons, in those with a history of previous TB, and with trace readouts. Methods We evaluated the relative accuracy of Xpert-MTB/RIF and Xpert-Ultra in 272 selected but well-characterized archived sputum samples. Of these, 168 were culture-positive (64/168 smear-positive and 104/168 smear-negative), and 104 were culture-negative (102/104 from patients with previous TB and 2/104 from patients without a TB history). Assay-specific limit-of-detection (LOD) experiments were conducted using serial dilutions of Mycobacterium tuberculosis H37Rv. Results Overall sensitivity (95%CI) in smear-negative culture-positive samples for Xpert-MTB/RIF and Xpert-Ultra were 71.2% (62.5–79.9) and 77% (68.9–85.1), respectively (and in HIV-infected persons: 63.5% (50–76.1) and 73.1% (61.1–85.2), respectively). The LOD for Xpert-Ultra was lower (9 versus 184 CFU/ml). There were a total of 9/272 (3.3%) Xpert Ultra trace readouts (6/104 [5.8%]) in smear-negative culture-positive persons, and 3/102 (3%) in culture-negative non-TB persons with a history of previous TB). Conclusions Xpert-Ultra had a lower LOD compared to Xpert-MTB/RIF. A small proportion of samples (5%) from culture-negative patients but with a history of previous TB had a likely false-positive trace readout. These data inform the management of patients with suspected TB in endemic settings.
机译:背景技术有关不同设置的Xpert-Ultra性能数据有限的数据,在艾滋病毒感染者中,在具有前一TB的历史的人中,以及痕量读数。方法评估Xpert-MTB / RIF和Xpert-Ultra的相对精度在272中选择但良好地表征的存档样品。其中,168种培养阳性(64/168污垢阳性和104/168涂抹阴性),104例是培养阴性(来自患者的患者102/104和2/104,没有TB历史的患者) 。使用分枝杆菌H37RV的连续稀释液进行测定的特异性检测限制(LOD)实验。结果XPERT-MTB / RIF和XPERT-Ultra的涂抹阴性培养阳性样品中的总体敏感性(95%CI)分别为71.2%(62.5-79.9)和77%(68.9-85.1)(以及艾滋病毒感染人:63.5%(50-76.1)和73.1%(61.1-85.2))。 Xpert-Ultra的LOD较低(9与184个CFU / mL)。共有9/272(3.3%)Xpert超痕量读数(6/104 [5.8%]),涂抹阴性培养阳性人和培养负非TB人员3/102(3%)凭前TB的历史)。结论与Xpert-MTB / RIF相比,Xpert-Ultra具有较低的床位。来自培养阴性患者的一小部分样品(<5%),但具有先前结核病的历史具有可能的假染色痕迹读数。这些数据可通知在流行环境中涉嫌结核病患者的管理。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号