Type 2 diabetes mellitus requires early, accurate, and efficient monitoring for best treatment. Current common diagnosis tools either test late-appearing symptoms, are low resolution, or are expensive in cost and time. A system of physiological models for the oral ingestion of glucose, subcutaneous injection of insulin, and glycaemic control, are used to generate a quantitative test for insulin sensitivity. The proposed test uses35gof oral glucose, 2.0 units of rapid-acting insulin, and both intra-venous and finger-prick blood samples for insulin, C-peptides, and blood glucose levels frequently over a 2-hour period. The test is developedin silicoto enable early and repetitive monitoring of the pathogenesis of type 2 diabetes. In conjunction with emerging technologies in insulin sensing and needle-free delivery and monitoring devices, there is a pathway with this test to provide more effective, efficient early diagnosis of diabetes risk.
机译:2型糖尿病需要早期,准确,高效的监测,以获得最佳治疗。目前常见的诊断工具测试晚期出现的症状,是低分辨率,或成本和时间昂贵。用于葡萄糖的口服摄入,皮下注射胰岛素和血糖控制的生理模型系统,用于产生胰岛素敏感性的定量测试。所提出的试验使用35g葡萄糖,2.0单位的快速作用胰岛素,以及胰岛素,C-肽和血糖水平的静脉内和指刺血样样品经常在2小时内常见。该试验均发育Silicoto能够提前和重复监测2型糖尿病的发病机制。结合胰岛素传感和无针递送和监测装置的新兴技术,有一个途径,该测试可以提供更有效,有效的糖尿病风险的早期诊断。