Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading

机译:近端接触强度对轴向负载下植入式悬臂固定部分假牙三维位移的影响

获取原文
           

摘要

Objective: This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture (CFPD) under vertically concentrated loading with digital laser speckle (DLS) technique. Methods: Fresh mandible of beagle dog was used to establish the implant-supported CFPD for specimen. DLS technique was employed for measuring the three-dimensional displacement of the prosthesis under vertically concentrated loading ranging from 200 to 3000 g. The effect of the contact tightness on the displacement of CFPD was investigated by means of changing the contact tightness. Results: When an axial concentrated loading was exerted on the pontic of the implant-supported CFPD, the displacement of the CFPD was the greatest. The displacement of the prosthesis decreased with the increase of contact strength. When the contact strength was 0, 0.95, and 3.25 N, the displacement of the buccolingual direction was smaller than that of the mesiodistal direction but greater than that of the occlusogingival direction. When the force on the contact area was 6.50 N, the mesiodistal displacement of the prosthesis was the biggest while the buccolingual displacement was the smallest. Conclusions: The implant-supported CFPD is an effective therapy for fully or partially edentulous patients. The restoration of the contact area and the selection of the appropriate contact strength can reduce the displacement of the CFPD, and get a better stress distribution. The most appropriate force value is 3.25 N in this study.
机译:目的:本研究研究了垂直浓缩装载下悬臂固定部分义齿(CFPD)的近端接触强度对具有数字激光散斑(DLS)技术的近侧接触强度的影响。方法:采用新鲜颌骨毛,用于建立标本的植入物支持的CFPD。使用DLS技术来测量垂直浓缩的垂直浓度的假体的三维位移,范围为200至3000g。通过改变接触紧张,研究了接触紧张对CFPD位移的影响。结果:当在植入物支持的CFPD的Pontic上施加轴向浓缩载荷时,CFPD的位移是最大的。随着接触强度的增加,假体的位移降低。当接触强度为0,0.95和3.25n时,颊孔方向的位移小于关系方向的位移,但大于咬合方向的位移。当接触面积的力为6.50 n时,假体的短生体位移是最大的,而Bucloling Peractement是最小的。结论:植入物支持的CFPD是全面或部分薄弱患者的有效疗法。接触面积的恢复和选择适当的接触强度可以减少CFPD的位移,并获得更好的应力分布。本研究中最合适的力量值是3.25 n。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号