首页> 外文期刊>Journal of Ophthalmology >Corneal Astigmatism Measurements Comparison among Ray-Tracing Aberrometry, Partial Coherence Interferometry, and Scheimpflug Imaging System
【24h】

Corneal Astigmatism Measurements Comparison among Ray-Tracing Aberrometry, Partial Coherence Interferometry, and Scheimpflug Imaging System

机译:射线追踪性变形,部分相干干扰测量和Scheimpflug成像系统之间的角膜散散测量比较

获取原文
           

摘要

Purpose. To investigate interdevice agreement among corneal topography/ray-tracing aberrometry (iTrace), partial coherence interferometry (IOLMaster), and Scheimpflug imaging (Pentacam) for the measurement of corneal astigmatism. Methods. The analysis included 90 eyes of 90 subjects without ocular disease. The main outcome measures were corneal cylinder power and axis of astigmatism. All corneal astigmatism measurements were converted to two perpendicular components by using vector analysis. Interdevice agreement was assessed using Bland–Altman analysis, paired sample t-test, and one-way analysis of variance. Results. No significant interdevice difference existed in the astigmatism magnitude, cardinal component, and oblique component (all P0.05). On comparing iTrace wavefront and simulated keratometry (SimK) astigmatism, significant differences were observed in the astigmatism magnitude and oblique component (both P0.01), but not in the cardinal component (P=0.687). On comparing Pentacam pupil 3 mm and corneal vertex 3 mm axial astigmatism, significant difference was observed in the astigmatism magnitude (P0.001), but not in the cardinal and oblique components (both P0.05). Conclusions. The iTrace, IOLMaster, and Pentacam devices could be used interchangeably for corneal astigmatism measurement. However, the measurement difference in iTrace wavefront and SimK astigmatism and Pentacam pupil 3 mm and vertex 3 mm axial astigmatism should be considered in clinic practice.
机译:目的。为了调查角膜地形/射线追踪变形体(ITRACE),部分相干干涉测量(IOLMASTER)和Scheimpflug成像(Pentacam)来调查互脱性协议,用于测量角膜散散。方法。分析包括90只眼睛,没有眼部疾病。主要结果测量是角膜气缸电源和散光轴。通过使用载体分析将所有角膜散差测量结果转化为两个垂直组分。使用Bland-Altman分析,配对样本T检验和方差单向分析评估互通协议。结果。在散光幅度,红衣主期组分和倾斜组分中没有显着的互脱差异(所有P> 0.05)。在比较ITRACE波前和模拟音轨(SIMK)散光中,在散光幅度和倾斜组分(P <0.01)中观察到显着差异,但不在基本组分中(P = 0.687)。在比较戊克蛹瞳孔3mm和角膜顶点3mm轴向散光上,在散光幅度(p <0.001)中观察到显着差异,但不在基本和倾斜组分中(P> 0.05)。结论。 ITRACE,IOLMASTER和PENTACAM器件可以互换用于角膜散差测量。然而,在临床实践中应考虑ITRACE波前和西叠散散和五叠曲面瞳孔3mm和顶点3mm轴向散光的测量差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号