摘要

Purpose. To compare the autofluorescence images of the Zeiss versus Topcon eye fundus cameras and design an objective way to quantify it.Procedures. The IMAGEJ software was used to determine the gray level corresponding to the darkest veins and the peripapillary ring (thresholds), the level of white of the brightest perifoveal area, their difference (contrast level), and the suprathreshold area for each photograph.Results. Carl Zeiss has higher contrast values than Topcon. The Topcon contrast presented a crest with further decline as the suprathreshold area continued to increase. On the contrary, the Zeiss profile did not decline in contrast.Conclusions and Message. The Carl Zeiss camera showed superior contrast ability over the Topcon when performing autofluorescence imaging. We set objective parameters to compare fundus cameras FAF images. These parameters could be the base to objectively measure and determine changes and realize followup to areas of hyper- or hypofluorescence.
机译:目的。比较蔡司的自发荧光图像与拓拓眼底形相机,并设计客观方式来量化它.Procedures。 imagej软件用于确定与最暗静脉和围栏的灰度相对应的灰度和阈值环(阈值),最亮的尖端区域的白色水平,它们的差异(对比度水平)和Suprathreshold区域。结果。 Carl Zeiss比Topcon更高的对比度值。随着Suprathreshold地区继续增加,Topcon对比度呈现出一个粗糙的冠冕。相反,蔡司剖面对比度没有下降。结论和信息。在进行自发荧光成像时,Carl Zeiss摄像机在Topcon上显示出卓越的对比度。我们设置了客观参数来比较眼底相机FAC图像。这些参数可以是客观测量和确定变化的基础,并实现高荧光区域的后续。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号