首页> 外文期刊>Journal of Materials Research and Technology >Performance analysis of optical and X-Ray transmitter sensors for limestone classification in the South of Brazil
【24h】

Performance analysis of optical and X-Ray transmitter sensors for limestone classification in the South of Brazil

机译:巴西南部石灰岩分类光学和X射线发射器传感器的性能分析

获取原文
       

摘要

The present study aims to evaluate the use of sensor-basedin the classification of marble ore. These dolomite marbles are quite particular due toa series of felsic and mafic intrusions and syngenetic metapelitic intercalation. In the present study, all the variants of ore and sterile that exists in the deposit were quantified using 3D mapping of mine’s surface. Three particles sizes were tested with the sorting equipment in the laboratory: ?25+9.5mm, ?50+25mm, and ?70+50mm. We use indices of recovery, in terms of Calcium Carbonate Equivalent and mass balance, but also performance indices as accuracy, sensitivity, and specificity for interpretation. Recovery values were between 35 and 85% in the lowest sieve range and between 91 and 98% in the larger range in the sorting tests withan optical sensor. Accuracy is between 43 and 85% in the lowest range and 97 and 98% in the largest. Same results occurred with the sensitivity and specificity, which had better separations while increasing the particle size. It was concluded that the X-ray sensor did not perform well and was considered not applicable to the case under analysis. The optical sensor was shown to be applicable in all tested situations, with recoveries between 35% and 98%, depending on the condition and particle size of the feed. The grain size was the primary factor influencing the separation performance, implying variations of up to 30% in the accuracy indexes.
机译:本研究旨在评估传感器的使用 - 基于大理石矿石的分类。这些白云石大理石特别适合Tour系列术术和迈涂侵入性和组织术语。在本研究中,使用矿山表面的3D绘图量化沉积物中存在的矿石和无菌的所有变体。用实验室中的分拣设备测试三种颗粒尺寸:25 + 9.5mm,?50 + 25mm,Δ0+ 50mm。我们在碳酸钙等同物和质量平衡方面使用恢复索引,但也可以作为准确性,敏感性和解释的特异性的性能指标。在含有光学传感器的分选测试中,恢复值在最低筛子范围内介于35至85%,在较大范围内为91至98%。精度在最低范围内43%至85%,最大的97%和98%。敏感性和特异性发生了相同的结果,其在增加粒度时具有更好的分离。得出结论是,X射线传感器没有表现良好,被认为是不适用于分析的情况。显示光学传感器在所有测试的情况下适用于所有测试情况,其回收率在35%和98%之间,这取决于进料的状况和粒度。粒度是影响分离性能的主要因素,暗示精度指标的变化高达30%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号