首页> 外文期刊>Journal of International Medical Research >Motion-corrected free-breathing late gadolinium enhancement combined with a gadolinium contrast agent with a high relaxation rate: an optimized cardiovascular magnetic resonance examination protocol
【24h】

Motion-corrected free-breathing late gadolinium enhancement combined with a gadolinium contrast agent with a high relaxation rate: an optimized cardiovascular magnetic resonance examination protocol

机译:运动纠正的自由呼吸晚钆增强与钆造影剂相结合,具有高松弛率:优化的心血管磁共振检查协议

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Objective This prospective study investigated the feasibility of an optimized cardiovascular magnetic resonance (CMR) examination protocol using the motion-corrected (MOCO), balanced steady-state free precession (bSSFP), phase-sensitive inversion recovery (PSIR) sequence combined with a gadolinium contrast agent with a high relaxation rate in patients who cannot hold their breath. Methods Fifty-one patients with heart disease underwent CMR examinations twice and these were performed with different late gadolinium enhancement (LGE) imaging sequences (fast low-angle shot [FLASH] sequence vs. MOCO sequence) and different gadolinium contrast agents (gadopentetate dimeglumine vs. gadobenate dimeglumine) with a 48-hour interval. LGE image quality, total time spent in the whole study, and time taken to perform LGE imaging were compared for the two CMR examinations. Results LGE images with the MOCO bSSFP PSIR sequence showed significantly higher image quality compared with those with the segmented FLASH PSIR sequence. There was a significant difference between the total scan time for the two examinations and different LGE sequences. Conclusions The MOCO bSSFP PSIR sequence effectively improves the quality of LGE images. Changing the CMR scanning protocol by combining the MOCO bSSFP PSIR sequence with a gadolinium contrast agent with a high relaxation rate effectively shortens the scan time. Clinical trial registration number: ChiCTR-ROC-17013978.
机译:目的该前瞻性研究调查了使用运动校正(MOCO),平衡稳态自由预防(BSSFP),相敏反恢复(PSIR)序列与钆相结合的优化心血管磁共振(CMR)检查方案的可行性造影剂具有高呼吸速度的弛豫率高。方法方法患有91例心脏病患者接受了CMR检查的两次,这些患者用不同晚期的钆增强(LGE)成像序列进行(快速低角度拍摄[闪光]序列与MOCO序列)和不同的钆造影剂(Gadopentetetate Dimeglumine Vs)进行。甘烷酸盐酸倍半月,间隔48小时。 LGE图像质量,在整个研究中花费的总时间,并比较了两种CMR检查的时间表所花费的时间。结果与具有分段的闪光PSIR序列相比,具有MoCo BSSFP PSIR序列的LGE图像显着更高的图像质量。两种检查和​​不同的LGE序列的总扫描时间之间存在显着差异。结论MOCO BSSFP PSIR序列有效提高了LGE图像的质量。通过将MoCo BSSFP PSIR序列与具有高弛豫速率的钆造影剂组合改变CMR扫描方案,有效地缩短了扫描时间。临床试验登记号码:CHICTR-ROC-17013978。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号