首页> 外文期刊>Journal of applied clinical medical physics / >Reducing contrast dose using virtual monoenergetic imaging for aortic CTA
【24h】

Reducing contrast dose using virtual monoenergetic imaging for aortic CTA

机译:使用虚拟单体成像对对比剂量进行主动脉CTA

获取原文
       

摘要

Three‐dimensional computed tomographic angiography (3D‐CTA) is widely used to evaluate the inner diameters of vessels and the anatomical vascular structure prior to endoscopic aortic surgery or transcatheter valve implantation. Virtual monoenergetic imaging (VMI) is a new application in dual‐energy CT (DECT). We evaluated the potential for contrast dose reduction in preoperative aortic CTA using VMI. To evaluate performance in terms of image quality and vessel shape, we quantified the contrast‐to‐noise ratio (CNR) and the vessel diameter using a cylinder phantom we developed, and used volume rendering to assess visual quality. All VMI had improved CNR values compared with conventional 120?kVp images at an iodine content of 15?mgI/mL. In each image, a virtual mono‐energy of 40?keV yielded the highest CNR value, and an iodine content of 9?mgI/mL was comparable to that of conventional images with an iodine content of 15?mgI/mL. The circularity indices (CI) of the vascular model at 15, 12, and 9?mgI/mL were similar to those of the reference condition using conventional voltages; however, CI was degraded at iodine contents of 6 and 3?mgI/mL with VMI. In the case of iodine content of 15?mgI/mL, VMI was superior, with conventional image by visual evaluation. In the cases of iodine contents of 12 and 9?mgI/mL, image quality was judged to be almost the same level when comparing 12 and 9?mgI/mL to conventional images. In the case of 6 and 3?mgI/mL, reference image using conventional technique was superior to that of VMI. We demonstrated in that decreasing contrast iodine content is possible using VMI with an energy of 40?keV for preoperative aortic 3D‐CTA.
机译:三维计算断层血管造影(3D-CTA)广泛用于评估血管内径和解剖学血管结构之前的内窥镜主动脉手术或经丝瓣植入前的内径。虚拟单齿性成像(VMI)是双能CT(DECT)的新应用。我们使用VMI评估了术前主动脉CTA对比剂量降低的可能性。为了评估图像质量和血管形状方面的性能,我们使用我们开发的气缸幻像量化对比度 - 噪声比(CNR)和血管直径,并使用体积渲染来评估视觉质量。与常规120 kVP图像相比,所有VMI均改善CNR值,其碘含量为15?MgI / ml。在每个图像中,40℃的虚拟单能量产生最高的CNR值,碘含量为9?MgI / ml与碘含量为15〜MgI / ml的常规图像的碘含量相当。血管模型的循环指数(CI)在15,12和9?MGI / mL中使用常规电压类似于参考条件的索引;然而,用VMI的碘含量在碘含量为6和3的碘/ ml。在碘含量为15?MgI / ml的情况下,VMI优异,通过视觉评估具有常规图像。在碘含量为12和9?MgI / mL的情况下,当比较12和9?MgI / ml至常规图像时,判断图像质量几乎是相同的水平。在6和3?MgI / ml的情况下,使用常规技术的参考图像优于VMI的参考图像。我们证明,使用VMI可以使用具有40Ω·keV的能量的VMI来证明对比度碘含量。术前主动脉3D-CTA。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号