首页> 外文期刊>Universidad Industrial de Santander. Revista. Salud >Adherencia y potenciales eventos adversos prevenidos durante la administraci?3n de medicamentos endovenosos empleando bombas de infusi?3n inteligentes en cuatro unidades de cuidados intensivos en Colombia
【24h】

Adherencia y potenciales eventos adversos prevenidos durante la administraci?3n de medicamentos endovenosos empleando bombas de infusi?3n inteligentes en cuatro unidades de cuidados intensivos en Colombia

机译:在哥伦比亚四个重症监护病房中使用智能infusi泵给予终身药物期间依赖于inovenos药物的粘附和潜在的不良事件

获取原文
           

摘要

Introduction: Smart infusion pumps have become a useful tool for the safe administration of intravenous medications, since they allow the prevention of potential adverse events. Objetive: To assess adherence and potential adverse events prevented during intravenous medication administration using smart infusion pumps. Methods: Observational study, conducted in four intensive care units using data from Hospira MedNetTM software. A descriptive analysis was carried out together with a bivariate analysis using a Mann-Whitney U test, a KruskalWallis test and a Bonferroni test to assess adherence and potential adverse events prevented by year and service. Results: Adherence was 74.0%, 78,299 safety alerts were presented and 4.54% (n = 16,288) potential adverse events were prevented. Differences were found between the first and second year in adherence [Median: 69.15 (Q1: 64.2-Q3:75.5) versus Median: 84.2 (Q1: 72.15-Q3: 89.05), p0.001]. Likewise safety adherence [Median: 87.1% (Q1: 83.05-Q3: 91.2) versus Median: 94.05 (Q1: 89.95-Q3: 96.2), p0.001] and the relative limit alert editions [Median: 17.0 (Q1: 8.5-Q3: 24.5) versus Median: 12.0 (Q1: 7.0-Q3: 17.5), p=0.013]. The saline solution, norepinephrine, ringer’s lactate, piperacillin-tazobactam, nitroglycerin and heparin presented the highest number of safety alerts. Conclusions: Adequate adherence (use of the drug library) and safety adherence (indicator of pump use) were found, with a reduction in potential adverse events; thus, the use of smart pumps could contribute to the prevention of potential errors during the administration of intravenous medications in the intensive care unit.
机译:简介:智能输注泵已成为安全静脉内药物的有用工具,因为它们允许预防潜在的不良事件。 Objetive:使用智能输注泵在静脉注射药物管理期间评估依从性和潜在的不良事件。方法:使用来自Hospira Mednettm软件的数据,在四个重症监护室进行的观察研究。使用Mann-Whitney U测试,Kruskalwallis测试和Bonferroni测试进行了描述性分析,并进行了kruskalwallis试验和Bonferroni测试,以评估年份和服务的依从性和潜在的不良事件。结果:依从性为74.0%,提出了78,299个安全警报,防止了4.54%(n = 16,288)潜在的不良事件。在遵守的第一和第二年之间发现了差异[中位数:69.15(Q1:64.2-Q3:75.5)与中位数:84.2(Q1:72.15-Q3:89.05),P <0.001]。同样安全遵守[中位数:87.1%(Q1:83.05-Q3:91.2)与中位数:94.05(Q1:89.95-Q3:96.2),P <0.001]和相对限制警报版[中位数:17.0(Q1:8.5- Q3:24.5)与中位数:12.0(Q1:7.0-Q3:17.5),P = 0.013]。盐水溶液,去甲肾上腺素,林格氏乳酸,哌啶蓟啶丙氨酸,硝基甘油和肝素呈现最多的安全警报。结论:发现有足够的粘附(使用药物库)和安全遵守(泵使用指示剂),减少潜在不良事件;因此,使用智能泵可能有助于预防在重症监护单元中静脉内药物的静脉内药物期间的潜在误差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号