首页> 外文期刊>Stroke Research and Treatment >Blood Flow Assessment of Arteriovenous Malformations Using Intraoperative Indocyanine Green Videoangiography
【24h】

Blood Flow Assessment of Arteriovenous Malformations Using Intraoperative Indocyanine Green Videoangiography

机译:使用术中吲哚菁绿色影像造影的动脉畸形血液流量评估

获取原文
       

摘要

Intraoperative indocyanine green (ICG) videoangiography is widely used in patients undergoing neurosurgery. FLOW800 is a recently developed analytical tool for ICG videoangiography to assess semi-quantitative flow dynamics; however, its efficacy is unknown. In this study, we evaluated its functionality in the assessment of flow dynamics of arteriovenous malformation (AVM) through ICG videoangiography under clinical settings. ICG videoangiography was performed in the exposed AVM in eight patients undergoing surgery. FLOW800 analysis was applied directly, and gray-scale and color-coded maps of the surgical field were obtained. After surgery, a region of interest was placed on the individual vessels to obtain time-intensity curves. Parameters of flow dynamics, including the maximum intensity, transit time, and cerebral blood flow index, were calculated using the curves. The color-coded maps provided high-resolution images; however, reconstruction of colored images was restricted by the depth, approach angle, and brain swelling. Semi-quantitative parameters were similar among the feeders, niduses, and drainers. However, a higher cerebral blood flow index was observed in the feeders of large AVM (3 cm) than in those of small AVM (P 0.05). Similarly, the cerebral blood flow index values were positively correlated with the nidus volume (P 0.01). FLOW800 enabled visualization of the AVM structure and safer resection, except in case of deep-seated AVM. Moreover, semi-quantitative values in the individual vessels through using ICG intensity diagram showed different patterns according to size of the AVM. ICG videoangiography showed good performance in evaluating flow dynamics of the AVM in patients undergoing surgery.
机译:术中吲哚菁绿(ICG)显像术广泛用于接受神经外科的患者。 Flow800是ICG型录像机最近开发的分析工具,以评估半定量流动动态;然而,它的功效是未知的。在这项研究中,我们通过ICG临床环境评估了通过ICG显影的动脉畸形(AVM)的评估中的功能。 ICG显像造影在接受手术的八名患者中进行了暴露的AVM。直接施加流量800分析,获得了手术场的灰度和彩色编码图。手术后,将感兴趣区域放置在各个血管上以获得时间强度曲线。使用曲线计算流动动力学的参数,包括最大强度,过渡时间和脑血流指数。颜色编码的地图提供了高分辨率图像;然而,彩色图像的重建受到深度,接近角度和脑肿胀的限制。进料器,潮气和排水机之间的半定量参数相似。然而,在大AVM(> 3cm)的饲养者中观察到比小AVM的饲养者更高的脑血流指数(P <0.05)。类似地,脑血流指数值与奈斯体积呈正相关(P <0.01)。 Flow800使AVM结构的可视化和更安全的切除,除了深度座椅AVM之外。此外,通过使用ICG强度图通过ICG强度图的半定量值显示了根据AVM的尺寸的不同图案。 ICG显像造影表现出良好的性能,评估手术患者的AVM流动动态。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号