首页> 外文期刊>South African Journal of Child Health >The effect of device position and use of transparent covers on the irradiance distribution of LED phototherapy devices
【24h】

The effect of device position and use of transparent covers on the irradiance distribution of LED phototherapy devices

机译:器件位置和透明盖对LED光疗装置辐照度分布的影响

获取原文
           

摘要

BACKGROUND. Effective phototherapy reduces neonatal jaundice and its complications. Irradiance increases as the distance of the light source decreases from a single phototherapy light. There are limited studies of the effect of distance and positional changes on different light-emitting diode (LED) light designs on achieving effective phototherapy. OBJECTIVES. To describe and compare the effect of distance, angle and plastic barriers on three different LED lights of different design. METHODS. Comparisons were made using a Servolite, a General Electric (GE) Lullaby and a Ningbo David LED phototherapy light. Measurements were done according to methods described by the International Electrotechnical Commission (IEC). The effective irradiated area was measured on a grid measuring 60 x 30 cm subdivided into 5 x 5 cm squares. Measurements were done for the following scenarios: light placed at the manufacturer's recommended distance, 20 cm closer, 20 cm further, at an angle, through clear plastic and through scuffed Perspex. RESULTS. When the lights were placed closer to the irradiated surface than the manufacturers' recommendations, the maximum irradiance increased, but the median irradiance and uniformity ratio decreased. When the lights were angled at 45?°, the median irradiance was decreased. A decrease in the median irradiance was also seen when phototherapy lights passed through scuffed plastic and food-grade plastic. CONCLUSION. Our study demonstrated that the placing of LED lights closer than the manufacturers' recommendations, the use of transparent barriers and the use of lights at an angle, compromised phototherapy irradiance and distribution. Only the GE light met IEC standards.
机译:背景。有效的光疗减少新生儿黄疸及其并发症。随着光源的距离从单个光疗光减小,辐照度增加。对不同发光二极管(LED)光设计的距离和位置变化的影响有限的研究实现了有效的光疗法。目标。描述并比较不同设计三种不同LED灯的距离,角度和塑性屏障的效果。方法。使用伺服石,一般电气(GE)LULLABY和宁波大卫LED光疗光进行比较。根据国际电工委员会(IEC)描述的方法进行测量。测量有效的照射区域,在70×30cm细分为5×5cm方形的网格上测量。测量完成了以下情景:放置在制造商推荐的距离,20厘米的光线较近20厘米,以一定角度,通过透明的塑料和磨损的Perspex进一步。结果。当灯比制造商的建议更接近照射表面时,最大辐照度增加,但中值辐照度和均匀比率降低。当灯在45Ω°角度时,中位辐照度降低。当光疗灯通过磨碎的塑料和食品级塑料时,还可以看到中位辐照度下降。结论。我们的研究表明,将LED灯放置比制造商的建议更近,使用透明屏障和使用灯以一定的角度,损害光疗辐照度和分布。只有GE LIGHT符合IEC标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号