Objective To demonstrate that human visual illusion can contribute to sub-endocardial dark rim artifact in contrast-enhanced myocardial perfusion magnetic resonance images. Materials and Methods Numerical phantoms were generated to simulate the first-passage of contrast agent in the heart, and rendered in conventional gray scale as well as in color scale with reduced luminance variation. Cardiac perfusion images were acquired from two healthy volunteers, and were displayed by the same gray and color scales used in the numerical study. Before and after k-space windowing, the left ventricle (LV)-myocardium boarders were analyzed visually and quantitatively through intensity profiles perpendicular the boarders. Results k-space windowing yielded monotonically decreasing signal intensity near the LV-myocardium boarder in the phantom images, as confirmed by negative finite difference values near the board ranging ?1.07 to ?0.14. However, the dark band still appears, which is perceived by visual illusion. Dark rim is perceived in the in-vivo images after k-space windowing that removed the quantitative signal dip, suggesting that the perceived dark rim is a visual illusion. The perceived dark rim is stronger at peak LV enhancement than the peak myocardial enhancement, due to the larger intensity difference between LV and myocardium. In both numerical phantom and in-vivo images, the illusory dark band is not visible in the color map due to reduced luminance variation. Conclusion Visual illusion is another potential cause of dark rim artifact in contrast-enhanced myocardial perfusion MRI as demonstrated by illusory rim perceived in the absence of quantitative intensity undershoot.
机译:目的探明人类视觉错觉可以有助于对比度增强的心肌灌注磁共振图像中的子内膜黑暗边缘伪影。产生材料和方法,产生数值模拟以模拟心脏中的造影剂的第一通道,并以传统的灰度以及具有降低的亮度变化的颜色刻度。心脏灌注图像是从两个健康的志愿者获得的,并且由数值研究中使用的相同灰色和彩色尺度显示。在K空间窗口之前和之后,通过垂直于寄宿生的强度分布在视觉上和定量地分析左心室(LV)-Myocardium登机机。结果K - 空间窗口在Phantom图像中的LV-MyeCardium登机器附近产生单调减小信号强度,如在电路板附近的负有限差值Δ1.07到?0.14所示。然而,暗带仍然出现,这是通过视觉错觉所感知的。在取下定量信号浸渍的k空间窗口之后,暗轮辋在体内图像中感知,表明感知的暗边缘是视觉错觉。由于LV和心肌之间的强度差异,所感知的黑暗轮辋比峰值心肌增强更强。在两个数值幽灵和体内图像中,由于亮度变化的亮度变化,在彩色图中不可见幻象暗带。结论视觉幻觉是对比增强的心肌灌注MRI中的暗缘伪影的另一个潜在原因,如没有定量强度下冲的幻象边缘所证明的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号