首页> 外文期刊>Medical principles and practice: international journal of the Kuwait University, Health Science Centre >Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty
【24h】

Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty

机译:高度多孔钛杯与羟基磷灰石涂层插座:中期导致相同等的双侧总髋关节置换术

获取原文
           

摘要

Objective: Highly porous titanium cups have been recently introduced, with contradictory outcomes. A retrospective consecutive case series involving bilateral metachronous total hip arthroplasties (THA) performed with 2 different cups, i.e., Fixa (F) and Fixa Ti-Por (T) (Adler Ortho, Milan, Italy), and the same stem, was evaluated. T sockets, manufactured using electron beam melting, were supposed to prove superior in terms of clinical results, survival rates, and radiographic parameters in comparison to hydroxyapatite-coated F cups with conventional porosity. Subjects and Methods: Twenty-four bilateral metachronous THAs with an F cup on one side and a T socket on the other side were evaluated. Preoperative and postoperative Harris hip scores (HHS) were collected for every patient. Radiographic signs of loosening were assessed. The radiographic signs of osseointegration (radiolucent lines, superolateral buttress, inferomedial buttress, radial trabeculae, and stress shielding) were evaluated. Results: No intraoperative complications occurred. The mean HHS score was excellent and comparable in both groups. At the mean follow-up of 134 months (F) and 79 months (T), no cup or liner revisions were performed. No radiographic signs of loosening were reported. All of the patients revealed 3 parameters of good bony ingrowth at least. Both groups showed similar radiographic parameters regarding osseointegration, which were stable over the time. Stress shielding was more evident in the T cohort ( p = 0.07). Conclusion: Highly porous titanium cups produced using an additive manufacturing and electron beam melting technology achieved reliable midterm clinical and radiographic results not inferior to those of second-generation cups.
机译:目的:最近介绍了高度多孔的钛杯,具有矛盾的结果。评估涉及双侧再叉续全部髋关节关节血管成型(THA)的回顾性连续案例系列用2种不同的杯子,即FIXA(F)和FIXA TI-POR(T)(Adler Ortho,米兰,意大利)和相同的茎。 。使用电子束熔化制造的T插座应该在临床结果,存活率和射线照相参数方面证明与常规孔隙率的羟基磷灰石涂层的F杯相比卓越。对象和方法:评估二十四个双侧与F杯上的双侧比赛,另一侧的T插座上进行了一面。为每个患者收集术前和术后哈里斯臀部分数(HHS)。评估放松释放的迹象。评估骨整合的放射线迹象(无辐射线,超基点支撑,犹豫不决的弯曲,桡动脉小梁和应力屏蔽)。结果:没有发生术中并发症。两组的平均HHS评分具有优异且可比性。在134个月(f)和79个月(t)的平均随访时,没有进行杯子或衬里修订。没有报道宽松放松的放射性迹象。所有患者至少揭示了3种良好的骨骼注入参数。两组均显示关于骨整合的相似射线照相参数,随着时间的推移是稳定的。在T COHORT中,应力屏蔽更明显(p = 0.07)。结论:使用添加剂制造和电子束熔化技术生产的高度多孔钛杯可靠的中期临床和射线照相结果不逊色于第二代杯子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号