...
首页> 外文期刊>Magnetic resonance in medical sciences : >Microstrip Transmission Line RF Coil for a PET/MRI Insert
【24h】

Microstrip Transmission Line RF Coil for a PET/MRI Insert

机译:用于PET / MRI插入件的微带传输线RF线圈

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Purpose: We proposed and developed a new microstrip transmission line radiofrequency (RF) coil for a positron emission tomography (PET) insert for MRI, which has low electrical interactions with PET shield boxes. We performed imaging experiments using a single-channel and a four-channel proposed RF coils for proof-of-concept.Methods: A conventional microstrip coil consists of a microstrip conductor, a ground conductor, and a dielectric between the two conductors. We proposed a microstrip coil for the PET insert that replaced the conventional single-layer ground conductor with the RF shield of the PET insert. A dielectric material, which could otherwise attenuate gamma photons radiated from the PET imaging tracer, was not used. As proof-of-concept, we compared conventional and the proposed single-channel coils. To study multichannel performance, we further developed a four-channel proposed RF coil. Since the MRI system had a single-channel transmission port, an interfacing four-way RF power division circuit was designed. The coils were implemented as both RF transmitters and receivers in a cylindrical frame of diameter 150 mm. Coil bench performances were tested with a network analyzer (Rohde & Schwarz, Germany), and a homogeneous phantom study was conducted for gradient echo imaging and RF field (Bsub1/sub) mapping in a 3T clinical MRI system (Verio, Siemens, Erlangen, Germany).Results: For all coils, the power reflection coefficient was below ?30 dB, and the transmission coefficients in the four-channel configuration were near or below ?20 dB. The comparative single-channel coil study showed good similarity between the conventional and proposed coils. The gradient echo image of the four-channel coil showed expected flashing image intensity near the coils and no phase distortion was visible. Transmit Bsub1/sub field map resembled the image performance.Conclusion: The proposed PET-microstrip coil performed similarly to the conventional microstrip transmission line coil and is promising for the development of a compact coil-PET system capable of simultaneous PET/MRI analysis with an existing MRI system.
机译:目的:我们提出并开发了一种新的微带传输线射频(RF)线圈,用于MRI的正电子发射断层扫描(PET)插入物,与PET屏蔽盒具有低电相互作用。我们使用单通道和四通道提出的RF线圈进行成像实验,用于概念验证。方法:传统的微带线圈由微带导体,接地导体和两个导体之间的电介质组成。我们提出了一种用于PET插入件的微带线圈,其用PET插入件的RF屏蔽替换传统的单层接地导体。不使用介电材料,否则可以否定从PET成像示踪剂辐射的伽马光子。作为概念验证,我们比较了传统和所提出的单通道线圈。为了研究多通道性能,我们进一步开发了一种四通道提出的RF线圈。由于MRI系统具有单通道传输端口,因此设计了一种连接四路RF功率分割电路。线圈被实现为直径150mm圆柱形框架中的RF发射器和接收器。用网络分析仪(Rohde&Schwarz,Germany)测试线圈台面性能,并对3T临床MRI系统中的梯度回声成像和RF场(B 1 )进行均匀的幻影研究( Verio,Siemens,Erlangen,德国)。对于所有线圈,功率反射系数低于?30dB,四通道配置中的传输系数近于或低于20 dB。比较单通道线圈研究表明传统和提出的线圈之间的良好相似性。四通道线圈的梯度回波图像显示在线圈附近的预期闪烁图像强度,并且不可见相位失真。传输B 1 字段图类似于图像性能。结论:所提出的宠物微带线圈与传统的微带传输线圈相似,并且很有希望开发能够同时的紧凑型线圈PET系统PET / MRI分析现有MRI系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号