首页> 外文期刊>EJVES Short Reports >Endovascular Retrieval of Fragmented Central Venous Access Device Catheters: A Management Protocol Based on Catheter Location
【24h】

Endovascular Retrieval of Fragmented Central Venous Access Device Catheters: A Management Protocol Based on Catheter Location

机译:血管内检索分散的中央静脉接入装置导管:基于导管位置的管理方案

获取原文

摘要

IntroductionFragmented central venous access device (CVAD) catheters can be retrieved percutaneously but a pertinent approach for catheters in various locations has not been addressed.ReportComparing 14 fragmented CVAD catheters managed with direct snaring with 35 catheters treated by a modified protocol with repositioning of intrapulmonary or intracardiac catheters (21/35 cases) to the inferior vena cava before snaring, the latter group had a shorter fluoroscopic time (23.0?±?10.6 vs. 11.0?±?4.0?min,P?=?0.005) and less chest symptoms (42.8% vs. 8.7%,P?=?0.011).ConclusionFragmented CVAD catheters managed with a modified protocol with repositioning before snaring are feasible with reductions in fluoroscopic time and chest symptoms.
机译:可以经过介绍额外的中心静脉接入装置(CVAD)导管,但是尚未解决各个位置中的导管的相关方法。预先征收了通过通过改性方案治疗的35个导管的直接捕获的碎片化的CVAD导管,重新定位血管内或血管内,用直接捕获35个导管的碎片化的CVAD导管。导管(21/35例)在咆哮前到下腔静脉,后一组荧光透视时间较短(23.0?±10.6与11.0?±4.0?min,p?=?0.005)和胸部症状更少( 42.8%vs.8.7%,p?= 0.011)。结论冲突的CVAD导管,用修饰方案管理,在捕获之前重新定位,可在荧光透视时间和胸部症状中减少。