Impact of implants number and attachment type on the peri-implant stresses and retention of palateless implant-retained overdenture

机译:植入物数量和附着类型对Peri-incomant胁迫的影响和无人植入物保留过度的滞留

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Objectives: To evaluate the impact of implants number and attachments type on the peri-implant stresses and retention of maxillary palateless implant-supported overdenture. Materials and Methods: Four edentulous maxillary educational acrylic resin models were used. According to the implants number and type of attachment used, four groups were compared: Group I, 2-locator attachments in the canine area; Group II, 2- OT equator attachments in the canine area; Group III, 4-locator attachments in the canine, second premolar area and Group IV, 4-OT equator attachments in the canine, second premolar area. Implants retained palateless overdenture was constructed on each model. Four self-protected linear strain gauges were cemented on each implant. A digital loading device was used to apply compressive loads to measure the resulting peri-implant stresses. Forcemeter and Universal testing machines were used to test the retention of palateless overdenture. Results: A significant difference between the same implant number and distribution with different attachments was found (P = 0.003, P = 0.020), respectively. Least stresses amount was found around the 4-implant locator palateless overdenture, while the highest was found around the 2-implant OT equator palateless overdenture. Nevertheless; the result was that 2-implant locator palateless overdenture recorded insignificant higher retentive forces than the 4-implant OT equator one. Conclusions: It can be concluded that the implant-retained palateless overdenture with four locator attachments is considered a promising treatment option regarding stress distribution. Using locator attachments, for implant-retained palateless overdenture with either two or four implants considering their superior retentive properties, is advantageous when compared to OT equator attachments.
机译:目的:评估植入物号码和附着类型对围植入胁迫和颌骨无人植入物支持过度的静脉胁迫的影响。材料与方法:使用四种薄膜上颌癌丙烯酸树脂模型。根据植入物数量和使用的附着类型,比较了四组:I族,犬面积中的2个定位器附件;第II族,犬区2- OT赤道附件; III组,犬的4个定位器附件,第二次掠过区域和第四组,犬的4个赤道附件,第二珠子区域。在每个模型上构建了植入物保留可覆盖的植入物。在每个植入物上粘合四个自我保护的线性应变仪。数字装载装置用于施加压缩载荷以测量所得到的PERI-植入物应力。用于测试不可覆盖的保留的支架和通用测试机器。结果:发现相同的植入数和分布与不同附件的分布之间的显着差异(p = 0.003,p = 0.020)。在4个植入物定位器上发现最少的压力量是不可覆盖的,而在2-植入式OT赤道上发现最高距离无人估计。尽管如此;结果是,2-植入定位器不可覆谱记录的微不足道的保留力比4植入式OT赤道较高。结论:可以得出结论,具有四个定位器附件的植入无人过度覆盖被认为是关于应力分布的有希望的治疗选择。使用定位器附件,对于考虑其优越的保持性能,与两种或四个植入物进行植入物固定的可植入物,与OT赤道附件相比是有利的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号