Background TIMI flow grade and corrected TIMI frame count (CTFC) are widely used methods to evaluate angiographic coronary blood flow. Measurement of coronary blood flow (CBF) on standard coronary angiography (CAG) has aroused great interest recently, trying to combine the CTFC concept with new methods for post-angioplasty and for cardiac syndrome X assessment. Additionally, coronary slow flow it is now considered a major criterion for microvascular angina. Objective Explore a new approach of quantitative angiographic measurement of CBF based on densitometric contrast detection in CAG off-line, using an accessible software to obtain a more precise and reliable CBF assessment. Methods Thirty patients were studied and divided in 2 groups, normal coronary blood flow (NF) and slow coronary blood flow (SF), according to CTFC definition. The DM was applied to the study sample to differentiate between NF and SF. Non-parametric statistics was used to assess differences between groups at p0.05. Results The DM normal reference value obtained for coronary blood flow was 9 [5–10] frames. NF vs SF group were compared and expressed as median [interquartile range], for the left anterior descending: 10 [7-11] vs 21 [8-33];p= 0.016; circumflex: 9 [4-13] vs 14 [11-30]; p= 0.012 and right coronary artery: 5 [3-11] vs 13 [8-26]; p=0.009. Conclusion The DM showed the feasibility of measuring coronary blood flow with precision, consistency and reproducible in a standard coronary angiogram, showing the additional capability to differentiate between NF and SF in chest pain patients with normal coronary arteries.
机译:背景技术Timi流量等级和校正的TIMI帧数(CTFC)是广泛使用的方法来评估血管造影冠状动脉血流。冠状动脉血流(CBF)对标准冠状动脉造影(CAG)的测量最近引起了极大的利益,试图将CTFC概念与新血管成形术和心脏综合征X评估结合起来。此外,冠状动脉慢速流动现在被认为是微血管心绞痛的主要标准。目的探讨CBF的数量血管造影测量方法,基于CAG离线对比度检测,使用可访问的软件获得更精确和可靠的CBF评估。方法根据CTFC定义,研究了三十名患者,分为2组,正常冠状动脉(NF)和慢冠状动脉血流(SF)。将DM应用于研究样本以区分NF和SF。非参数统计用于评估P <0.05之间的组之间的差异。结果冠状动脉血流获得的DM正常参考值为9 [5-10]框架。比较NF VS SF组,并表示为中位数[四分位数范围],左前期下降:10 [7-11] Vs 21 [8-33]; P = 0.016; Circurex:9 [4-13] Vs 14 [11-30]; p = 0.012和右冠状动脉:5 [3-11] Vs 13 [8-26]; p = 0.009。结论DM在标准冠状动脉血管造影中测量冠状动脉血流测量冠状动脉血流的可行性,呈现出患有正常冠状动脉胸痛患者NF和SF之间的额外能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号