首页> 外文期刊>Annals of laboratory medicine. >Comparison Between the SFTS-QS Kit and the PowerChek SFTSV Real-time PCR Kit for the Detection of Severe Fever With Thrombocytopenia Syndrome Virus
【24h】

Comparison Between the SFTS-QS Kit and the PowerChek SFTSV Real-time PCR Kit for the Detection of Severe Fever With Thrombocytopenia Syndrome Virus

机译:SFTS-QS套件与PowerChek SFTSV实时PCR套件的比较检测血小板减少症综合征病毒

获取原文
       

摘要

The recent increase in severe fever with thrombocytopenia syndrome (SFTS) cases has led to the development of the SFTS-QS kit (MiCoBioMed, Seongnam, Korea) for detecting the SFTS virus (SFTSV, now renamed Huaiyangshan banyangvirus). SFTS-QS is a qualitative real-time reverse transcription PCR assay based on lab-on-a-chip technology. We evaluated the performance of the SFTS-QS kit and compared it with that of the PowerChek SFTSV Real-time PCR kit (PowerChek; Kogene Biotech, Seoul, Korea). A total of 117 serum samples were simultaneously assayed using the SFTS-QS and PowerChek kits. Sanger sequencing targeting the S and M segments of SFTSV was performed as the reference method. The total turnaround time of the two kits was compared. The SFTS-QS results agreed with those of PowerChek with a kappa value of 0.92. The diagnostic sensitivity and specificity of the SFTS-QS kit were both 100% (14/14 and 103/103, respectively), whereas those of the PowerChek kit were 100% (14/14) and 98.1% (101/103), respectively. The results of SFTS-QS and PowerChek were comparable; however, the SFTS-QS kit required a shorter total turnaround time. The SFTS-QS kit produced accurate and fast results and thus could serve as a useful tool for detecting SFTSV.
机译:近期对血小板减少症综合征(SFT)案例的严重发烧的增加导致了SFTS-QS套件(Micobiomed,Seongnam,韩国)的发展,用于检测SFTS病毒(SFTSV,现在更名为淮阳山Banyangvirus)。 SFTS-QS是一种基于实验室技术的定性实时逆转录PCR测定。我们评估了SFTS-QS套件的性能,并将其与PowerChek SFTSV实时PCR套件进行比较(PowerChek; Kogene Biotech,首尔,韩国)。使用SFTS-QS和PowerChek试剂盒同时测定117个血清样品。靶向SFTSV的S和M区段的Sanger测序作为参考方法进行。比较了两个套件的总周转时间。 SFTS-QS结果与Powerchek的SFTS-QS结果同意,Kappa值为0.92。 SFTS-QS试剂盒的诊断敏感性和特异性分别为100%(分别为14/14和103/103),而PowerChek试剂盒的诊断均为100%(14/14)和98.1%(101/103),分别。 SFTS-QS和PowerChek的结果是可比的;但是,SFTS-QS套件需要较短的总周转时间。 SFTS-QS套件产生准确和快速的结果,因此可以作为检测SFTSV的有用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号