Systems of Electronic Overcurrent Protection in Pulse Power Generator Operating on Plasma Load

机译:脉冲发电机在等离子体负载下操作的电子过流保护系统

获取原文
           

摘要

Schematic peculiarities of pulsed power source and modulator-shaper for working on high instability plasma load are discussed. In its construction should be provided for several levels of overcurrent protection. First of all modules of electronic protection should be integrated into the control driver system of IGBT modules and must provide a quick disconnect power switches in excess of the allowable values of pulse current. The next level of overcurrent protection in pulse power generator is a protection against overcurrent in the load circuit. Operating threshold of current protection in this case must be set to the maximum value of current in the secondary circuit. In order to limit the emission of stray voltage on the power pulses in a moment of switching of power switches a restrictive RC snubbers parallel to the collectors and the emitters of transistors must be installed. It is also appropriate application of software-controlled configurating of electrical power at the outputof a pulsed power supply.
机译:讨论了用于加工高不稳定性等离子体载荷的脉冲电源和调制器的示意性特性。在其建筑中,应提供几个水平的过流保护。首先,所有电子保护模块应集成到IGBT模块的控制驱动器系统中,必须提供超出脉冲电流允许值的快速断开电源开关。脉冲发电机中的下电流保护水平是对负载电路的过电流的保护。在这种情况下,电流保护的操作阈值必须设置为辅电路中电流的最大值。为了限制电力切换的动力脉冲上的功率脉冲上的杂散电压的发射,必须安装与收集器平行的限制性RC缓冲器和晶体管的发射器。它还适当地在脉冲电源输出时应用软件控制的电力电力。